Empty tank handling
The Empty Tank Handling function facilitates surface tracking close to the tank bottom for
products with a low dielectric constant. Such products are relatively transparent for
microwaves, and strong echoes from the tank bottom may interfere with the relatively
weak measurement signal from the surface. Using this function may therefore improve
measurement performance when the product surface is close to the tank bottom.
In case the product surface echo is lost in the Empty Tank Detection Area close to the tank
bottom, the device will enter Empty Tank state and an Invalid Level alarm is triggered.
Figure 4-26: Empty Tank Configuration
The Extra Echo Detection function is used for tanks with a dome or conical bottom shape
provided the tank bottom does not produce a strong echo when the tank is empty. For
tanks with a conical bottom, an echo may appear beneath the actual tank bottom when
the tank is empty. If the device is not able to detect the tank bottom this function can be
used to ensure that the device stays in empty tank state as long as this extra echo is
present.
For further details see
Reference Manual
Configuration
00809-0100-5901
September 2019
Rosemount 5900C Radar Level Gauge
191
Summary of Contents for Rosemount 5900C
Page 1: ...Reference Manual 00809 0100 5901 Rev DA September 2019 Rosemount 5900C Radar Level Gauge ...
Page 6: ...Contents Reference Manual September 2019 00809 0100 5901 vi Reference Manual ...
Page 12: ...Introduction Reference Manual September 2019 00809 0100 5901 12 Reference Manual ...
Page 116: ...Installation Reference Manual September 2019 00809 0100 5901 116 Reference Manual ...
Page 204: ...Configuration Reference Manual September 2019 00809 0100 5901 204 Reference Manual ...
Page 208: ...Operation Reference Manual September 2019 00809 0100 5901 208 Reference Manual ...
Page 290: ...Product Certifications Reference Manual September 2019 00809 0100 5901 290 Reference Manual ...