Cause
The core processor software update failed.
Recommended actions
1. Resolve any active alerts.
2. Check the connection between the transmitter and the core processor.
3. Reboot or power-cycle the transmitter, then retry the procedure.
4. Contact customer service.
17.13.48 Enhanced Event
X
Active
Alert
Event Active
Cause
The conditions assigned to any enhanced event (Enhanced Event 1 through Enhanced Event 5) are present.
Recommended actions
1. If this is an accurate indication of process conditions, no action is required. The alert will clear when the
process returns to normal.
2. Review event configuration if you believe the event was triggered erroneously.
17.13.49 Event
X
Active
Alert
Event Active
Cause
The conditions assigned to either Basic Event 1 or Basic Event 2 are present.
Recommended actions
1. If this is an accurate indication of process conditions, no action is required. The alert will clear when the
process returns to normal.
2. Review event configuration if you believe the event was triggered erroneously.
17.13.50 Frequency Input Saturated
Alert
Output Saturated
Cause
The input frequency is greater than 3500 Hz.
Recommended actions
1. Check the scaling of the Frequency Input.
Troubleshooting
Configuration and Use Manual
March 2019
MMI-20025166
278
Micro Motion Model 5700 Transmitters with Configurable Outputs