Overview
Use
Status Alarm Severity
to control the fault actions that the transmitter performs when it
detects an alarm condition.
Restrictions
•
For some alarms,
Status Alarm Severity
is not configurable.
•
For some alarms,
Status Alarm Severity
can be set only to two of the three options.
Tip
Micro Motion recommends using the default settings for
Status Alarm Severity
unless you have a
specific requirement to change them.
Procedure
1.
Select a status alarm.
2.
For the selected status alarm, set
Status Alarm Severity
as desired.
Option
Description
Fault
Actions when fault is detected:
•
The alarm is posted to the Alert List.
•
Outputs go to the configured fault action (after
Fault Timeout
has expired, if
applicable).
•
Digital communications go to the configured fault action (after
Fault Timeout
has expired, if applicable).
•
The status LED (if available) changes to red or yellow (depending on alarm se-
verity).
Actions when alarm clears:
•
Outputs return to normal behavior.
•
Digital communications return to normal behavior.
•
The status LED (if available) returns to green and may or may not flash.
Informa-
tional
Actions when fault is detected:
•
The alarm is posted to the Alert List.
•
The status LED (if available) changes to red or yellow (depending on alarm se-
verity).
Actions when alarm clears:
•
The status LED (if available) returns to green and may or may not flash.
Ignore
No action
Status alarms and options for Status Alarm Severity
Configure device options and preferences
Configuration and Use Manual
91
Summary of Contents for MICRO MOTION 2700
Page 10: ...Getting Started 2 Micro Motion Model 2700 Transmitters with Analog Outputs ...
Page 14: ...Before you begin 6 Micro Motion Model 2700 Transmitters with Analog Outputs ...
Page 26: ...Configuration and commissioning 18 Micro Motion Model 2700 Transmitters with Analog Outputs ...
Page 84: ...Configure process measurement 76 Micro Motion Model 2700 Transmitters with Analog Outputs ...
Page 214: ...Measurement support 206 Micro Motion Model 2700 Transmitters with Analog Outputs ...
Page 258: ...Troubleshooting 250 Micro Motion Model 2700 Transmitters with Analog Outputs ...
Page 354: ...Default values and ranges 346 Micro Motion Model 2700 Transmitters with Analog Outputs ...
Page 373: ......