9.4.3
View and acknowledge alerts using ProLink III
You can view a list containing all alerts that are active, or inactive and have been
unacknowleged. From this list, you can acknowlege individual alerts or choose to
acknowledge all alerts at once.
1.
View alerts on the ProLink III main screen under
Alerts
.
All active or unacknowledged alarms are listed, and displayed according to the
following categories:
Category
Description
Failed: Fix Now
A meter failure has occurred and must be addressed immediately.
Maintenance: Fix Soon
A condition has occurred that can be fixed at a later time.
Advisory: Informational
A condition has occurred, but requires no maintenance from you.
Notes
•
All fault alerts are displayed in the
Failed: Fix Now
category.
•
All information alerts are displayed in either the
Maintenance: Fix Soon
category or the
Advisory: Informational
category. The category assignment is hard-coded.
•
The transmitter automatically filters out alerts with
Alert Severity
set to
Ignore
.
2.
To acknowledge a single alert, check the
Ack
checkbox for that alert. To
acknowledge all alerts at once, click
Ack All
.
Postrequisites
•
To clear the following alarms, you must correct the problem, acknowledge the
alarm, then power-cycle the transmitter: A001, A002, A010, A011, A012, A013,
A018, A019, A022, A023, A024, A025, A028, A029, A031.
•
For all other alarms:
-
If the alarm is inactive when it is acknowledged, it will be removed from the list.
-
If the alarm is active when it is acknowledged, it will be removed from the list
when the alarm condition clears.
9.4.4
View alarms using the Field Communicator
You can view a list containing all alarms that are active, or inactive but unacknowledged.
•
To view active or unacknowledged alarms, press
Service Tools
>
Alerts
.
All active alarms or unacknowledged alarms are listed.
Note
Only Fault and Informational alarms are listed. The transmitter automatically filters out alarms
with
Status Alarm Severity
set to
Ignore
.
Transmitter operation
156
Micro Motion
®
Model 2700 Transmitters with Analog Outputs
Summary of Contents for MICRO MOTION 2700
Page 10: ...Getting Started 2 Micro Motion Model 2700 Transmitters with Analog Outputs ...
Page 14: ...Before you begin 6 Micro Motion Model 2700 Transmitters with Analog Outputs ...
Page 26: ...Configuration and commissioning 18 Micro Motion Model 2700 Transmitters with Analog Outputs ...
Page 84: ...Configure process measurement 76 Micro Motion Model 2700 Transmitters with Analog Outputs ...
Page 214: ...Measurement support 206 Micro Motion Model 2700 Transmitters with Analog Outputs ...
Page 258: ...Troubleshooting 250 Micro Motion Model 2700 Transmitters with Analog Outputs ...
Page 354: ...Default values and ranges 346 Micro Motion Model 2700 Transmitters with Analog Outputs ...
Page 373: ......