Option
Setup
Polling for tempera-
ture
a. Ensure that the primary mA output has been wired to support
HART polling.
b. Choose
Online
>
Configure
>
Manual Setup
>
Measurements
>
External
Pressure/Temperature
>
Temperature
.
c. Enable
External Temperature
.
d. Choose
Online
>
Configure
>
Manual Setup
>
Measurements
>
External
Pressure/Temperature
>
External Polling
.
e. Set
Poll Control
to
Poll As Primary Host
or
Poll as Secondary Host
.
f. Choose an unused polling slot.
g. Set
External Tag
to the HART tag of the external temperature de-
vice.
h. Set
Polled Variable
to
Temperature
.
Tip
•
Poll as Primary
: No other HART masters will be on the network.
•
Poll as Secondary
: Other HART masters will be on the network.
The Field Communicator is not a HART master.
A value written by
digital communica-
tions
a. Choose
Online
>
Configure
>
Manual Setup
>
Measurements
>
External
Pressure/Temperature
>
Temperature
.
b. Enable
External Temperature
.
c. Perform the necessary host programming and communications
setup to write temperature data to the transmitter at appropri-
ate intervals.
Note
If the Weights & Measures application is implemented and the trans-
mitter is secured, digital communications cannot be used to write
temperature data to the transmitter.
7.
Online
>
Configure
>
Manual Setup
>
Measurements
>
Conc Measurement (CM)
>
CM
Configuration
and set
Active Matrix
to the matrix to be used for measurement.
Concentration process variables are now available on the transmitter. You can view and
report them in the same way that you view and report other process variables.
4.8.4
Standard matrices for the concentration measurement
application
The standard concentration matrices available from Micro Motion are applicable for a
variety of process fluids.
See
for a list of the standard concentration matrices available from
Micro Motion, along with the density and temperature measurement units used in
calculation, and the unit used to report concentration data.
Configure process measurement
66
Micro Motion
®
Model 2700 Transmitters with Analog Outputs
Summary of Contents for MICRO MOTION 2700
Page 10: ...Getting Started 2 Micro Motion Model 2700 Transmitters with Analog Outputs ...
Page 14: ...Before you begin 6 Micro Motion Model 2700 Transmitters with Analog Outputs ...
Page 26: ...Configuration and commissioning 18 Micro Motion Model 2700 Transmitters with Analog Outputs ...
Page 84: ...Configure process measurement 76 Micro Motion Model 2700 Transmitters with Analog Outputs ...
Page 214: ...Measurement support 206 Micro Motion Model 2700 Transmitters with Analog Outputs ...
Page 258: ...Troubleshooting 250 Micro Motion Model 2700 Transmitters with Analog Outputs ...
Page 354: ...Default values and ranges 346 Micro Motion Model 2700 Transmitters with Analog Outputs ...
Page 373: ......