N
Number of pulses per flow unit, as configured in the receiving device
The resulting
Frequency Factor
must be within the range of the frequency output (0 to
10,000 Hz):
•
If
Frequency Factor
is less than1 Hz,reconfigure the receiving device for a higher
pulses/unit setting.
•
If
Frequency Factor
is greater than 10,000 Hz, reconfigure the receiving device for a
lower pulses/unit setting.
Tip
If
Frequency Output Scale Method
is set to
Frequency=Flow
, and
Frequency Output Maximum Pulse Width
is set
to a non-zero value, Micro Motion recommends setting
Frequency Factor
to a value below 200 Hz.
Example: Configure
Frequency=Flow
You want the frequency output to report all flow rates up to 2000 kg/min.
The frequency receiving device is configured for 10 pulses/kg.
Solution:
FrequencyFactor =
x 10
2000
60
333.33
FrequencyFactor =
FrequencyFactor =
x N
RateFactor
T
Set parameters as follows:
•
Rate Factor
:
2000
•
Frequency Factor
:
333.33
6.3.4
Configure Frequency Output Maximum Pulse Width
Display
Not available
ProLink II
ProLink
>
Configuration
>
Frequency/Discrete Output
>
Frequency
>
Freq Pulse Width
ProLink III
Device Tools
>
Configuration
>
I/O
>
Outputs
>
Frequency Output
Field Communicator
Configure
>
Manual Setup
>
Inputs/Outputs
>
Frequency Output
>
FO Settings
>
Max Pulse Width
Overview
Frequency Output Maximum Pulse Width
is used to ensure that the duration of the ON signal is
great enough for your frequency receiving device to detect.
Integrate the meter with the control system
112
Micro Motion
®
Model 2700 Transmitters with Analog Outputs
Summary of Contents for MICRO MOTION 2700
Page 10: ...Getting Started 2 Micro Motion Model 2700 Transmitters with Analog Outputs ...
Page 14: ...Before you begin 6 Micro Motion Model 2700 Transmitters with Analog Outputs ...
Page 26: ...Configuration and commissioning 18 Micro Motion Model 2700 Transmitters with Analog Outputs ...
Page 84: ...Configure process measurement 76 Micro Motion Model 2700 Transmitters with Analog Outputs ...
Page 214: ...Measurement support 206 Micro Motion Model 2700 Transmitters with Analog Outputs ...
Page 258: ...Troubleshooting 250 Micro Motion Model 2700 Transmitters with Analog Outputs ...
Page 354: ...Default values and ranges 346 Micro Motion Model 2700 Transmitters with Analog Outputs ...
Page 373: ......