Date
Version
Type
Change
Operating in-
struction
09/2006
5.x
Expansion
Discrete output assignable as a flow switch
20001715 B
Discrete output fault indication configurability
Discrete input support for multiple action as-
signments
Added support for querying the display LED sta-
tus via Modbus
Additional HART and Modbus commands
Process comparator expanded to five configura-
ble events
Factory configuration restore function
Factory zero restore function
Alarm history expanded
Selectable write protection for configuration da-
ta
Expanded selection of source assignments for
mA output
Expanded storage of mA range values
Expanded custody transfer application for inde-
pendent implementation of NTEP and OIML
compliance
Adjustment
Display improvements for floating-point data
Feature
Configurable alarm severity
Gas standard volume functionality
Meter verification availability as an option
Multiple display language selections
09/2009
6.x
Expansion
Frequency output configurable as discrete out-
put on Series 1000 transmitters
20001715 BA
Discrete output assignable as flow switch on
Series 1000 transmitters
Display Variable 1 optionally fixed to process var-
iable assigned to primary mA output
Frequency output scaling method and related
parameters configurable from display
For enhanced density and petroeum measure-
ment process variables, display cycles among
variable name, current value and unit, and refer-
ence temperature
NE 53 history
Configuration and Use Manual
355
Summary of Contents for MICRO MOTION 2700
Page 10: ...Getting Started 2 Micro Motion Model 2700 Transmitters with Analog Outputs ...
Page 14: ...Before you begin 6 Micro Motion Model 2700 Transmitters with Analog Outputs ...
Page 26: ...Configuration and commissioning 18 Micro Motion Model 2700 Transmitters with Analog Outputs ...
Page 84: ...Configure process measurement 76 Micro Motion Model 2700 Transmitters with Analog Outputs ...
Page 214: ...Measurement support 206 Micro Motion Model 2700 Transmitters with Analog Outputs ...
Page 258: ...Troubleshooting 250 Micro Motion Model 2700 Transmitters with Analog Outputs ...
Page 354: ...Default values and ranges 346 Micro Motion Model 2700 Transmitters with Analog Outputs ...
Page 373: ......