The density factor is the change in fluid density, in g/cm
3
/PSI. When entering the
value, reverse the sign.
Example:
If the density factor is 0.000006 g/cm
3
/PSI, enter
−
0.000006
g/cm3/PSI.
6.
Set
Pressure Source
to the method that the transmitter will use to obtain pressure
data.
Option
Description
Poll for external value
The transmitter will poll an external pressure device, using
HART protocol over the primary mA output.
Static or Digital Communications
The transmitter will use the pressure value that it reads from
memory.
•
Static: The configured value is used.
•
Digital Communications: A host writes transmitter data
to transmitter memory.
Note
If the Weights & Measures application is implemented and
the transmitter is secured, digital communications cannot
be used to write temperature data to the transmitter.
7.
If you chose to poll for pressure data:
a. Select the
Polling Slot
to use.
The transmitter has two polling slots. You can use one for pressure and the other
for temperature, if concentration measurement or petroleum measurement is
enabled.
b. Set
Polling Control
to
Poll as Primary
or
Poll as Secondary
, and click
Apply
.
Tip
•
Poll as Primary
: No other HART masters will be on the network.
•
Poll as Secondary
: Other HART masters will be on the network. The Field Communicator
is not a HART master.
c. Set
External Device Tag
to the HART tag of the external pressure device, and click
Apply
.
8.
If you chose to use a static pressure value:
a. Set
Pressure Unit
to the desired unit.
b. Set
Static or Current Pressure
to the value to use, and click
Apply
Configure process measurement
72
Micro Motion
®
Model 2700 Transmitters with Analog Outputs
Summary of Contents for MICRO MOTION 2700
Page 10: ...Getting Started 2 Micro Motion Model 2700 Transmitters with Analog Outputs ...
Page 14: ...Before you begin 6 Micro Motion Model 2700 Transmitters with Analog Outputs ...
Page 26: ...Configuration and commissioning 18 Micro Motion Model 2700 Transmitters with Analog Outputs ...
Page 84: ...Configure process measurement 76 Micro Motion Model 2700 Transmitters with Analog Outputs ...
Page 214: ...Measurement support 206 Micro Motion Model 2700 Transmitters with Analog Outputs ...
Page 258: ...Troubleshooting 250 Micro Motion Model 2700 Transmitters with Analog Outputs ...
Page 354: ...Default values and ranges 346 Micro Motion Model 2700 Transmitters with Analog Outputs ...
Page 373: ......