Status alarms and recommended actions
(continued)
Table 12-2:
Alarm code
Description
Recommended actions
A117
Density Overrange (Petrole-
um)
1. Check your process conditions against the values reported
by the flowmeter.
2. Verify the configuration of the petroleum measurement ta-
ble type and density.
A118
Discrete Output 1 Fixed
The discrete output has been configured to send a constant val-
ue.
A120
Curve Fit Failure (Concentra-
tion)
Verify the configuration of the concentration measurement ap-
plication.
A121
Extrapolation Alarm (Concen-
tration)
If the product in the sensor has temperature or density proper-
ties that are outside the parameters established by the concen-
tration measurement curve, this is a symptom and no action is
required. This alarm should clear when the process fluid returns
to normal.
If the problem persists, check the configuration of the concen-
tration measurement application.
A131
Meter Verification in Progress:
Outputs to Last Measured Val-
ue
Meter verification in progress, with outputs set to
Last Measured
Value
.
A132
Sensor Simulation Active
Simulation mode is enabled.
A133
EEPROM Error (Display)
Change the display module. If the problem persists, contact
Micro Motion.
A141
DDC trigger(s) have comple-
ted
No action required.
N/A
Density FD Calibration in Pro-
gress
No action required.
N/A
Density D1 Calibration in Pro-
gress
No action required.
N/A
Density D2 Calibration in Pro-
gress
No action required.
N/A
Density D3 Calibration in Pro-
gress
No action required.
N/A
Density D4 Calibration in Pro-
gress
No action required.
N/A
Zero Calibration in Progress
No action required.
N/A
Reverse Flow
No action required.
Troubleshooting
Configuration and Use Manual
219
Summary of Contents for MICRO MOTION 2700
Page 10: ...Getting Started 2 Micro Motion Model 2700 Transmitters with Analog Outputs ...
Page 14: ...Before you begin 6 Micro Motion Model 2700 Transmitters with Analog Outputs ...
Page 26: ...Configuration and commissioning 18 Micro Motion Model 2700 Transmitters with Analog Outputs ...
Page 84: ...Configure process measurement 76 Micro Motion Model 2700 Transmitters with Analog Outputs ...
Page 214: ...Measurement support 206 Micro Motion Model 2700 Transmitters with Analog Outputs ...
Page 258: ...Troubleshooting 250 Micro Motion Model 2700 Transmitters with Analog Outputs ...
Page 354: ...Default values and ranges 346 Micro Motion Model 2700 Transmitters with Analog Outputs ...
Page 373: ......