6 RASP5 Speed controller
6.7 Configure special settings
Rapid Link 5 · RAMO5 · RASP5
10/19 MN034004EN
www.eaton.com
147
6.7.3 Phase change
For RASP5, parameter P6-08 changes the rotary field at the output from
FWD to REV. The control logic and the LED signals stay in the FWD function.
6.7.4 Stop behavior
RASP5 units do not require an external 24 VDC control voltage.
However, with their AS interface connection, RASP5 can be used to deceler-
ate the motor to a controlled stop in the event that the connection’s external
24 V DC voltage drops out with the second ramp (P2-13). To do this, the
24 V DC voltage must be supplied via the AS-interface connection
M12.
→
Parameters should only be changed by expert users as specified
in the manual.
Para-
meter
Designation
Description
Unit
Min
Max
DS
P6-08
Change Phase sequence
Motor
Changes the sequence of the output phases.
This prevents, that two phases of the motor cable have to be
changed in case the motor runs in the wrong direction.
0: U, V, W (cw)
1: U, W, V (ccw)
–
0
1
0
Para-
meter
Designation
Description
Unit
Min
Max
DS
P3-11
t-dec Select B0
Deceleration Ramp Select Bit 0
External stop function:
0: deactivated
1: Enabled
–
0
1
0
Summary of Contents for Rapid Link RAMO5
Page 1: ...Manual Rapid Link 5 RAMO5 RASP5 10 19 MN034004EN ...
Page 4: ...II ...
Page 10: ...6 Rapid Link 5 RAMO5 RASP5 10 19 MN034004EN www eaton com ...
Page 122: ...4 Operation 4 3 Manual control 118 Rapid Link 5 RAMO5 RASP5 10 19 MN034004EN www eaton com ...
Page 158: ...8 PC tool 8 2 Parameter Editor 154 Rapid Link 5 RAMO5 RASP5 10 19 MN034004EN www eaton com ...
Page 208: ...11 Communications 11 5 OP Bus 204 Rapid Link 5 RAMO5 RASP5 10 19 MN034004EN www eaton com ...