10 Parameter list
10.3 Parameter groups for RAMO
168
Rapid Link 5 · RAMO5 · RASP5
10/19 MN034004EN
www.eaton.com
10.3.4 Parameter group 3 (“Mechanical brake and digital inputs”)
Table 30:
Parameter group 3 (“Digital inputs/outputs”)
Para
meter
Designation
Description
Unit
Min
Max
DS
P3-04
Brake M-Level Release
Determines the time before the mechanical brake is
released.
s
0
2.50
0
P3-05
Brake Release Delay
Determines the time between the signal to close the brake
and disabling of the drive.
s
0
25.00
0
P3-06
DI1 Logic
0 = normally open
1 = normally closed
Note:
Change only after POWER ON/OFF active
–
0
1
0
P3-07
DI2 Logic
0 = normally open
1 = normally closed
Note:
Change only after POWER ON/OFF active
–
0
1
0
P3-08
DI3 Logic
0 = normally open
1 = normally closed
Note:
Change only after POWER ON/OFF active
P3-09
DI4 Logic
0 = normally open
1 = normally closed
Note:
Change only after POWER ON/OFF active
P3-10
DI5 Logic
0 = normally open
1 = normally closed
Note:
Change only after POWER ON/OFF active
P3-11
t-dec Select B0
Selection deceleration ramp bit 0
External stop function
0: deactivated
1: activated
Summary of Contents for Rapid Link RAMO5
Page 1: ...Manual Rapid Link 5 RAMO5 RASP5 10 19 MN034004EN ...
Page 4: ...II ...
Page 10: ...6 Rapid Link 5 RAMO5 RASP5 10 19 MN034004EN www eaton com ...
Page 122: ...4 Operation 4 3 Manual control 118 Rapid Link 5 RAMO5 RASP5 10 19 MN034004EN www eaton com ...
Page 158: ...8 PC tool 8 2 Parameter Editor 154 Rapid Link 5 RAMO5 RASP5 10 19 MN034004EN www eaton com ...
Page 208: ...11 Communications 11 5 OP Bus 204 Rapid Link 5 RAMO5 RASP5 10 19 MN034004EN www eaton com ...