2 Engineering
2.14 Regenerative braking
Rapid Link 5 · RAMO5 · RASP5
10/19 MN034004EN
www.eaton.com
73
Table 14:
Parameters for brake chopper
Para-
meter
Designation
Description
Unit
Min
Max
DS
P4-05
Brake chopper on
Parameter function only for devices with internal braking resistor
0 = deactivated
1 = active in RUN
2 = active in RUN and STOP
–
0
2
2
ATTENTION
The motor’s metal enclosure must always be grounded, irre-
spective of the type and version of motor cable used!
ATTENTION
When using RAMO5 or RASP5 units, do
not
connect external
brakes directly (to U, V, or W) inside the motor's terminal box!