10 Parameter list
10.4 Parameter groups for RASP
178
Rapid Link 5 · RAMO5 · RASP5
10/19 MN034004EN
www.eaton.com
10.4.3 Parameter group 2 (“Extended functions”)
Table 36:
Parameter group 2 (“Extended functions”)
Para-
meter
Designation
Description
Unit
Min
Max
DS
P2-01
f-Fix2
Preset Fixed Frequency 2
Value can be adjusted between f-min and f-max. Selection
via a digital control signal.
Hz/rpm
P1-02
P1-01
30 Hz
P2-02
f-Fix3
Preset Fixed Frequency 3
Value can be adjusted between f-min and f-max. Selection
via a digital control signal.
Hz/rpm
P1-02
P1-01
40 Hz
P2-03
f-Fix4
Preset Fixed Frequency 4
Value can be adjusted between f-min and f-max. Selection
via a digital control signal.
Hz/rpm
P1-02
P1-01
50 Hz
P2-04
f-Fix5
Preset Fixed Frequency 5
Value can be adjusted between f-min and f-max. Selection
via a digital control signal.
Hz/rpm
P1-02
P1-01
10 Hz
P2-05
f-Fix6
Preset Fixed Frequency 6
Value can be adjusted between f-min and f-max. Selection
via a digital control signal.
Hz/rpm
P1-02
P1-01
15 Hz
P2-06
f-Fix7
Preset Fixed Frequency 7
Value can be adjusted between f-min and f-max. Selection
via a digital control signal.
Hz/rpm
P1-02
P1-01
20 Hz
P2-07
f-Fix8
Preset Fixed Frequency 8
Value can be adjusted between f-min and f-max. Selection
via a digital control signal.
Hz/rpm
P1-02
P1-01
25 Hz
P2-08
t-SRamp1
Curve shape, temporal S-shape
Linear acceleration and deceleration time according to P1-
03 and P1-04.
Timed slured Transition to Start and End of Acceleration
(P1-03) and Deceleration Ramps (P1-04).
The time set here applies to both ramps. 0.0 = linear.
s
0
10
0
P2-09
Overvoltage Control
The over voltage control prevents the drive from tripping in
case of regenerative energy feedback from the motor to
the DC link. When disabled, the drive will trip “Over
Voltage” instead of automatically increasing the motor
ramp times.
-
0
1
1
P2-10
REV Enable
Activates or deactivates reverse rotation of the motor
0: REV activated - motor is running forward and revers
1: REV deactivated - motor is only forward
-
0
1
0
P2-11
t-acc2
Sets the acceleration ramp time 2 in seconds.
s
0
3000
5.0
P2-12
n-accMulti1
Frequency / speed, at which the acceleration ramp
changes from t-acc1 to t-acc2.
This can be set to any value between 0 and “f-max” (P1-01)
“Motor Nom Speed” (P1-10) = 0, displayed in Hz.
”Motor Nom Speed” (P1-10) > 0, displayed in rpm.
Frequency/Speed > P2-12 = t-acc2
Frequency/Speed < P2-12 = t-acc1
Hz/rpm
0
P1-01
0
P2-13
t-dec2
Sets the deceleration ramp time 2 in seconds.
Activation via pin 4 at AS-i.
s
0
3000
5.0
Summary of Contents for Rapid Link RAMO5
Page 1: ...Manual Rapid Link 5 RAMO5 RASP5 10 19 MN034004EN ...
Page 4: ...II ...
Page 10: ...6 Rapid Link 5 RAMO5 RASP5 10 19 MN034004EN www eaton com ...
Page 122: ...4 Operation 4 3 Manual control 118 Rapid Link 5 RAMO5 RASP5 10 19 MN034004EN www eaton com ...
Page 158: ...8 PC tool 8 2 Parameter Editor 154 Rapid Link 5 RAMO5 RASP5 10 19 MN034004EN www eaton com ...
Page 208: ...11 Communications 11 5 OP Bus 204 Rapid Link 5 RAMO5 RASP5 10 19 MN034004EN www eaton com ...