2 Engineering
2.9 Sensor inputs I1 and I2
60
Rapid Link 5 · RAMO5 · RASP5
10/19 MN034004EN
www.eaton.com
The input signals of the sensors at I1 and I2 are either incorporated directly in
the internal controller of RAMO5 and RASP5 and transmitted to a higher-
level PLC through AS-Interface
. The signal adaptation and integration into
the controller sequence is carried out via parameter P1-13.
Figure 26: Connection to sensor inputs (RASP5 as an example)
Y connector
→
RASP only!
With the optional Y-connector RA-XM12-Y up to four sensors
can be connected to these two M12 sockets.
SEN I1/I3
AS-I
Data
Fault
I1
Q1
I4
I2
I3
SEN I2/I4
STO
≦ 20 m
(≦ 65.6 ft)
1
2
Y connector RA-XM12-Y
Optical or inductive
sensors
N/O contact
N/C contact
Sensor cables coding
Mechanical sensors
“A“-coded
(IEC/EN
1 = brown
2 = white
3 = blue
4 = black
1
3
2
4
1
3
2
4
1
3
2
4
1
3
4
1
4
1
4
1
3
4
1
4
1
4
Summary of Contents for Rapid Link RAMO5