2 Engineering
2.8 STO function
52
Rapid Link 5 · RAMO5 · RASP5
10/19 MN034004EN
www.eaton.com
2.8.4 Direct release
Figure 22: STO control signal terminals (direct enable)
Without the connection of a power supply (24 V DC) to control signal
terminals 3 and 4, the RASP5 control section and the inverter will remain
blocked. An
Inhibit
(Inhibit = block) message is displayed.
The LED
STO
does not appear.
Pin
Configuration
1
+24 V DC
2
0 V (reference potential)
3
STO- (0 V)
4
STO + (+24 V DC)
→
Pin 2 (0V) must always be connected to pin 3 (STO-) and pin 4
(STO+) must always be connected to pin 1 (+24 V)!
WARNING
This function is not suitable for continuous operation!
→
For applications without a safety function, devices without STO
function can be used.
4
3
1
2