10 Parameter list
10.4 Parameter groups for RASP
Rapid Link 5 · RAMO5 · RASP5
10/19 MN034004EN
www.eaton.com
185
P5-08
NETReceivePZD4
Configuration of the 4th process data word PDI-4 from the
network master to the drive during cyclic communication.
0: reserved
1: User defined ramp times with 2 decimal places
2: User register 3. Configuration with Function Block Editor.
3: User register 4. Configuration with Function Block Editor.
–
0
3
0
P5-09
PointerToParameter
Pointer to an internal variable
P5-09 defines the internal variable (or the parameter),
whose value is displayed with P0-59. In addition the value
can be transferred to a fieldbus master via Process Data
Word 3 (PZD3, to be set with P5-05) or 4 (PZD4, to be set
with P5-06). P5-09 is monstly used in conjunction with the
Function Block Editor.
–
0
200
0
P5-10
Disable QuickStop
0: Quick stop via sensors deactivated
1: Quick stop via sensors activated; DQ3 signal active
–
0
1
0
Para-
meter
Designation
Description
Unit
Min
Max
DS