10 Parameter list
10.4 Parameter groups for RASP
Rapid Link 5 · RAMO5 · RASP5
10/19 MN034004EN
www.eaton.com
189
10.4.9 Parameter P1-13
Table 42:
Signal detection in manual mode
Table 43:
Signal detection in auto mode
Manual mode
P1-13
SI1
SI2
SI3
SI4
0
–
–
–
–
1
No function
No function
No function
No function
2
No function
No function
No function
No function
3
No function
No function
No function
No function
4
Stop in FWD mode for edge or
signal control
Stop in REV mode for edge or
signal control
No function
No function
5
Stop in FWD mode with edge
control
Stop in FWD mode with edge
control
Operation with fixed frequency 1
(FF1) for edge control
Operation with fixed frequency 1
(FF1) for edge control
6
No function
No function
No function
No function
7
Stop in FWD mode with edge
control
Stop in REV mode with edge
control
FWD operation with fixed
frequency 1 (FF1) for edge or
signal control
REV operation with fixed
frequency 1 (FF1) for edge or
signal control
8
Stop in FWD mode for edge or
signal control
Stop in REV mode for edge or
signal control
FWD operation with fixed
frequency 1 (FF1) for edge or
signal control
REV operation with fixed
frequency 1 (FF1) for edge or
signal control
Auto mode
P1-13
SI1
SI2
SI3
SI4
0
–
–
–
–
1
No function
No function
No function
No function
2
Stop in FWD mode for edge or
signal control
Stop in REV mode with edge
control
No function
No function
3
Stop in FWD or REV mode for
edge or signal control
No function
No function
No function
4
Stop in FWD mode for edge or
signal control
Stop in REV mode with edge
control
No function
No function
5
Stop in FWD mode for edge or
signal control
Stop in FWD mode with edge
control
Operation with fixed frequency 1
(FF1) for edge control
Operation with fixed frequency 1
(FF1) for edge control
6
Stop in FWD mode for edge or
signal control
Stop in REV mode with edge
control
FWD operation with fixed
frequency 1 (FF1) for edge or
signal control
REV operation with fixed
frequency 1 (FF1) for edge or
signal control
7
Stop in FWD mode for edge or
signal control
Stop in REV mode with edge
control
FWD operation with fixed
frequency 1 (FF1) for edge or
signal control
REV operation with fixed
frequency 1 (FF1) for edge or
signal control
8
Stop in FWD mode for edge or
signal control
Stop in REV mode with edge
control
FWD operation with fixed
frequency 1 (FF1) for edge or
signal control
REV operation with fixed
frequency 1 (FF1) for edge or
signal control
Summary of Contents for Rapid Link RAMO5
Page 1: ...Manual Rapid Link 5 RAMO5 RASP5 10 19 MN034004EN ...
Page 4: ...II ...
Page 10: ...6 Rapid Link 5 RAMO5 RASP5 10 19 MN034004EN www eaton com ...
Page 122: ...4 Operation 4 3 Manual control 118 Rapid Link 5 RAMO5 RASP5 10 19 MN034004EN www eaton com ...
Page 158: ...8 PC tool 8 2 Parameter Editor 154 Rapid Link 5 RAMO5 RASP5 10 19 MN034004EN www eaton com ...
Page 208: ...11 Communications 11 5 OP Bus 204 Rapid Link 5 RAMO5 RASP5 10 19 MN034004EN www eaton com ...