6 RASP5 Speed controller
6.6 LED Indicators
Rapid Link 5 · RAMO5 · RASP5
10/19 MN034004EN
www.eaton.com
141
Figure 94: RASP5 Block diagram
a
RASP5-…-xxxR…
b
RASP5-xx1… (180 V DC)
RASP5-xx2… (230/277 V AC)
RASP5-xx4… (400/480 V AC)
c
RASP5-…-xxxxxx1xx (FAN)
d
RASP5-…-xxx1...
e
RASP5-…-xxxxx1xxx (STO)
6.6 LED Indicators
The LEDs indicators of motor control unit RASP5 display the operating states
and allow a quick diagnosis.
LED
Display
Description
FWD
Clockwise rotating field
of motor voltage (U-V-W)
Off
Not actuated
Green
enabled (RUN-Mode)
Flashing
(green)
controlled:
• but inhibited through quick stop function of sensor inputs
• but inhibited because the key switch was in position MANUAL when
the supply voltage
(400 V or AS interface) was switched on.
→
Reset order required.
• STO signal present (inhibit)
REV
Counterclockwise rotating field
of motor voltage (W-V-U)
Off
Not actuated
Green
enabled (RUN-Mode)
Flashing
(green)
controlled:
• but inhibited through quick stop function of sensor inputs
• but inhibited because the key-operated switch was in the MANUAL
position when the supply voltage(400 V or AS-i) was switched on.
→
Reset order required
• STO signal present (inhibit)
AS interface
Off
No supply voltage in the AS-i electronics:
→
Check AS interface connection cables
→
Check AS interface power supply unit (master control)
Green
Communication active, normal operation
Red
Green Flashing
No communication:
• RASP5 not entered or entered with the wrong address (ID).
Flashing
Green/Red
AS interface address = 0:
→
AS interface setting the address
Green
Red flashing
→
fatal peripheral error; internal ASi error
I1
Sensor input I1
Off
• not connected
• Not triggered (no input signal)
Green
SI1 triggered (input signal)
REV
OFF
FWD
PWR
FLT
AS-I
Data
Fault
OFF/RESET
SEN I1/I3
I1
SEN I2/I4
I2
I3
I4
STO
FAN
Summary of Contents for Rapid Link RAMO5
Page 1: ...Manual Rapid Link 5 RAMO5 RASP5 10 19 MN034004EN ...
Page 4: ...II ...
Page 10: ...6 Rapid Link 5 RAMO5 RASP5 10 19 MN034004EN www eaton com ...
Page 122: ...4 Operation 4 3 Manual control 118 Rapid Link 5 RAMO5 RASP5 10 19 MN034004EN www eaton com ...
Page 158: ...8 PC tool 8 2 Parameter Editor 154 Rapid Link 5 RAMO5 RASP5 10 19 MN034004EN www eaton com ...
Page 208: ...11 Communications 11 5 OP Bus 204 Rapid Link 5 RAMO5 RASP5 10 19 MN034004EN www eaton com ...