3 Installation
3.2 Installation instructions
Rapid Link 5 · RAMO5 · RASP5
10/19 MN034004EN
www.eaton.com
81
The enclosure base can now be rotated, for example by 90° counterclock-
wise (to the left). The power terminals now point to the right.
Finally carefully refit the enclosure cover.
With the four screws secure the enclosure cover on the base.
Tighten the screws in two passes, always tightening two diagonally opposite
screws at a time. For example, tighten all four screws to about 2 Nm and
then to 3 Nm, always working in a crosswise pattern.
ATTENTION
Do not reach into the opened base or the enclosure cover!
as this can damage assemblies and connections and impair the
device’s function.
→
When assembling, make sure that the rubber seals are seated
correctly (protection type IP65).