Ordering numbers, Harmonic filters
Harmonic filters are used to reduce mains harmonics
• AHF 010: 10% current distortion
• AHF 005: 5% current distortion
380-415 V, 50Hz
I
AHF,N
Typical Motor Used
[kW]
Danfoss ordering number
VLT 5000
AHF 005
AHF 010
10 A
4, 5.5
175G6600
175G6622
5006, 5008
19 A
7.5
175G6601
175G6623
5011
26 A
11
175G6602
175G6624
5016
35 A
15, 18.5
175G6603
175G6625
5022, 5027
43 A
22
175G6604
175G6626
5032
72 A
30, 37
175G6605
175G6627
5042, 5052
101 A
45. 55
175G6606
175G6628
5062, 5072
144 A
75
175G6607
175G6629
5102
180 A
90
175G6608
175G6630
5122
217 A
110
175G6609
175G6631
5152
289 A
132, 160
175G6610
175G6632
5202, 5252
324 A
175G6611
175G6633
370 A
200
175G6688
175G6691
5302
Higher ratings can be achieved by paralleling the filter units
434 A
250
Two 217 A units
5352
578 A
315
Two 289 A units
5452
613 A
355
289 A and 324 A units
5502
648 A
400
Two 324 A units
5552
Please note that the matching of the typical Danfoss frequency converter and filter is pre-calculated based on
400 V and assuming typical motor load (4 or 2 pole motor): VLT 5000 series is based on a max. 160 % torque
application. The pre-calculated filter current may be different than the input current ratings of VLT 5000 as stated
in the respective operating instructions, as these numbers are based on different operating conditions.
440-480 V, 60Hz
I
AHF,N
Typical Motor Used
[HP]
Danfoss ordering number
VLT 5000
AHF 005
AHF 010
19 A
10, 15
175G6612
175G6634
5011, 5016
26 A
20
175G6613
175G6635
5022
35 A
25, 30
175G6614
175G6636
5027, 5032
43 A
40
175G6615
175G6637
5042
72 A
50, 60
175G6616
175G6638
5052, 5062
101 A
75
175G6617
175G6639
5072
144 A
100, 125
175G6618
175G6640
5102, 5122
180 A
150
175G6619
175G6641
5152
217 A
200
175G6620
175G6642
5202
289 A
250
175G6621
175G6643
5252
324 A
300
175G6689
175G6692
5302
370 A
350
175G6690
175G6693
5352
Higher ratings can be achieved by paralleling the filter units
506 A
450
217 A and 289 A units
5452
578 A
500
Two 289 A units
5502
648 A
600
Two 324 A units
5552
Please note that the matching of the typical Danfoss frequency converter and filter is pre-calculated based on
480 V and assuming typical motor load (4 or 2 pole motor): VLT 5000 series is based on a max. 160 % torque
application. The pre-calculated filter current may be different than the input current ratings of VLT 5000 as stated
in the respective operating instructions, as these numbers are based on different operating conditions.
VLT
®
5000 Series
MG.51.C5.22 - VLT
p
is a registered Danfoss trademark.
39
Technical data
Summary of Contents for VLT 5000 Series
Page 2: ...VLT 5000 Instruction Manual ...
Page 3: ......
Page 185: ...VLT 5000 Series 182 MG 51 C5 22 VLT p is a registered Danfoss trademark ...
Page 186: ...VLT 5000 Series MG 51 C5 22 VLT p is a registered Danfoss trademark 183 EC EMC ...
Page 197: ...EXTERNAL PRESET VLT 5000 Series 194 MG 51 C5 22 VLT p is a registered Danfoss trademark ...
Page 202: ...VLT 5000 Series MG 51 C5 22 VLT p is a registered Danfoss trademark 199 List of functions ...
Page 217: ...VLT 5000 Series 214 MG 51 C5 22 VLT p is a registered Danfoss trademark ...
Page 239: ......