Compact, AC line supply 3 x 380-500 V
According to international requirements
VLT type 5122
5152
5202
5252
5302
Normal overload current (110%):
Output current
I
VLT,N
[A] (380-440 V) 212
260
315
395
480
I
VLT, MAX
(60 s) [A] (380-440
V)
233
286
347
434
528
I
VLT,N
[A] (441-500 V) 190
240
302
361
443
I
VLT, MAX
(60 s) [A] (441-500
V)
209
264
332
397
487
Output
S
VLT,N
[kVA] (400 V) 147
180
218
274
333
S
VLT,N
[kVA] (460 V) 151
191
241
288
353
S
VLT,N
[kVA] (500 V) 165
208
262
313
384
Typical shaft output
[kW] (400 V) 110
132
160
200
250
[HP] (460 V) 150
200
250
300
350
[kW] (500 V) 132
160
200
250
315
High overload torque (160 %):
Output current
I
VLT,N
[A] (380-440 V) 177
212
260
315
395
I
VLT, MAX
(60 s) [A] (380-440
V)
266
318
390
473
593
I
VLT,N
[A] (441-500 V) 160
190
240
302
361
I
VLT, MAX
(60 s) [A] (441-500
V)
240
285
360
453
542
Output
S
VLT,N
[kVA] (400 V) 123
147
180
218
274
S
VLT,N
[kVA] (460 V) 127
151
191
241
288
S
VLT,N
[kVA] (500 V) 139
165
208
262
313
Typical shaft output
[kW] (400 V) 90
110
132
160
200
[HP] (460 V) 125
150
200
250
300
[kW] (500 V) 110
132
160
200
250
Max. cable cross-section to
motor
[mm
2
]
4,6
[AWG]
2,4,6
2 x 70
2 x 2/0
2 x 185
2 x 350 mcm
Max. cable cross-section to
load sharing and brake
[mm
2
]
4,6
[AWG]
2,4,6
2 x 70
2 x 2/0
2 x 185
2 x 350 mcm
Normal overload current (110%):
Rated input current
I
L,N
[A] (380-440 V) 208
256
317
385
467
I
L,N
[A] (441-500 V) 185
236
304
356
431
High overload torque (160 %):
Rated input current
I
L,N
[A] (380-440 V) 174
206
256
318
389
I
L,N
[A] (441-500 V) 158
185
236
304
356
Max. cable cross-section
power supply
[mm
2
]
4,6
[AWG]
2,4,6
2 x 70
2 x 2/0
2 x 185
2 x 350 mcm
Max. pre-fuses (line) [-]/UL
[A]
1
300/
300
350/
350
450/
400
500/
500
630/
600
Efficiency
3
0,98
Power loss
Normal overload [W] 2619
3309
4163
4977
6107
High overload [W] 2206
2619
3309
4163
4977
Weight
IP 00 [kg] 82
91
112
123
138
Weight
IP 21/NEMA 1 [kg] 96
104
125
136
151
Weight
IP 54/NEMA 12 [kg] 96
104
125
136
151
Enclosure
IP 00, IP 21/NEMA 1 and IP 54/NEMA 12
1. For type of fuse, see section
Fuses.
2. American Wire Gauge.
3. Measured using 100 ft [30 m] shielded motor cables at rated load and rated frequency.
4. Max. cable cross-section is the maximum possible cable cross-section allowed to be fitted on the terminals. Always comply with
national and local regulations on min. cable cross-section.
5. Weight without shipping container.
6. Connection bolt power supply and motor: M10; Brake and load sharing: M8
VLT
®
5000 Series
MG.51.C5.22 - VLT
p
is a registered Danfoss trademark.
21
Technical data
Summary of Contents for VLT 5000 Series
Page 2: ...VLT 5000 Instruction Manual ...
Page 3: ......
Page 185: ...VLT 5000 Series 182 MG 51 C5 22 VLT p is a registered Danfoss trademark ...
Page 186: ...VLT 5000 Series MG 51 C5 22 VLT p is a registered Danfoss trademark 183 EC EMC ...
Page 197: ...EXTERNAL PRESET VLT 5000 Series 194 MG 51 C5 22 VLT p is a registered Danfoss trademark ...
Page 202: ...VLT 5000 Series MG 51 C5 22 VLT p is a registered Danfoss trademark 199 List of functions ...
Page 217: ...VLT 5000 Series 214 MG 51 C5 22 VLT p is a registered Danfoss trademark ...
Page 239: ......