Outputs
terminal no.
42
45
01(relay)
04 (relay)
parameter
319
321
323
326
Value:
0-100 Hz
ය
0-20 mA
(0-100 Hz = 0-20 mA)
[36]
[36]
0-100 Hz
ය
4-20 mA
(0-100 Hz = 4-20 mA)
[37]
[37]
0-100 Hz
ය
0-32000 p
(0-100 Hz = 0-32000P)
[38]
[38]
0 - f
MAX
ය
0-20 mA
(0-FMAX = 0-20 mA)
[39]
[39]
0 - f
MAX
ය
4-20 mA
(0-FMAX = 4-20 mA)
[40]
[40]
0 - f
MAX
ය
0-32000 p
(0-FMAX = 0-32000P)
[41]
[41]
Ref
MIN
- Ref
MAX
ය
0-20 mA
(REF MIN-MAX = 0-20 mA)
[42]
[42]
Ref
MIN
- Ref
MAX
ය
4-20 mA
(REF MIN-MAX = 4-20 mA)
[43]
[43]
Ref
MIN
- Ref
MAX
ය
0-32000 p
(REF MIN-MAX = 0-32000P)
[44]
[44]
FB
MIN
- FB
MAX
ය
0-20 mA
(FB MIN-MAX = 0-20 mA)
[45]
[45]
FB
MIN
- FB
MAX
ය
4-20 mA
(FB MIN-MAX = 4-20 mA)
[46]
[46]
FB
MIN
- FB
MAX
ය
0-32000 p
(FB MIN-MAX = 0-32000P)
[47]
[47]
0 - I
MAX
ය
0-20 mA
(0-IMAX = 0-20 mA)
[48]
[48]
0 - I
MAX
ය
4-20 mA
(0-IMAX = 4-20 mA)
[49]
[49]
0 - I
MAX
ය
0-32000 p
(0-IMAX = 0-32000P)
[50]
[50]
0 - T
LIM
ය
0-20 mA
(0-TLIM = 0-20 mA)
[51]
[51]
0 - T
LIM
ය
4-20 mA
(0-TLIM = 4-20 mA)
[52]
[52]
0 - T
LIM
ය
0-32000 p
(0-TLIM = 0-32000P)
[53]
[53]
0 - T
NOM
ය
0-20 mA
(0-TNOM = 0-20 mA)
[54]
[54]
0 - T
NOM
ය
4-20 mA
(0-TNOM = 4-20 mA)
[55]
[55]
0 - T
NOM
ය
0-32000 p
(0-TNOM = 0-32000P)
[56]
[56]
0 - P
NOM
ය
0-20 mA
(0-PNOM = 0-20 mA)
[57]
[57]
0 - P
NOM
ය
4-20 mA
(0-PNOM = 4-20 mA)
[58]
[58]
0 - P
NOM
ය
0-32000 p
(0-PNOM = 0-32000P)
[59]
[59]
0 - SyncRPM
ය
0-20 mA
(0-SYNCRPM = 0-20 mA)
[60]
[60]
0 -SyncRPM
ය
4-20 mA
(0-SYNCRPM = 4-20 mA)
[61]
[61]
0 - SyncRPM
ය
0-32000 p
(0-0-SYNCRPM = 0-32000 p)
[62]
[62]
0 - RPM at FMAX
ය
0-20 mA
(0-RPMFMAX = 0-20 mA)
[63]
[63]
0 - RPM at FMAX
ය
4-20 mA
(0-RPMFMAX = 4-20 mA)
[64]
[64]
0 - RPM at FMAX
ය
0-32000 p
(0-RPMFMAX = 0-32000 p)
[65]
[65]
319
Terminal 42, output
(AO 42 FUNCT.)
Function:
This output can act both as a digital and an analogue
output. If used as a digital output (data value [0]-[65]),
a 24 V DC signal is transmitted; if used as an analogue
output either a 0-20 mA signal, a 4-20 mA signal or a
pulse output is transmitted.
Description of choice:
Control ready
, the frequency converter is ready for use;
the control card receives supply voltage.
Ready signal
, the frequency converter control card is
receiving a supply signal and the frequency converter
is ready for operation.
Ready, remote control
, the frequency converter control
card is receiving a supply signal and parameter 002
has been set to
remote control.
Enable, no warning
, the frequency converter is ready
for use; no start or stop command has been given
(start/disable). No warning.
Running
is active when there is a start command or the
output frequency is above 0.1 Hz. Is also active during
ramp down.
Running, no warning
, the output frequency is higher
than the frequency set in parameter 123. A start com-
mand has been given. No warning.
Runs in range, no warning
, runs within the programmed
current/frequency ranges set in parameters 223-226.
VLT
®
5000 Series
= factory setting, () = display text, [] = value for use in communication via serial communication port
118
MG.51.C5.22 - VLT
p
is a registered Danfoss trademark.
Summary of Contents for VLT 5000 Series
Page 2: ...VLT 5000 Instruction Manual ...
Page 3: ......
Page 185: ...VLT 5000 Series 182 MG 51 C5 22 VLT p is a registered Danfoss trademark ...
Page 186: ...VLT 5000 Series MG 51 C5 22 VLT p is a registered Danfoss trademark 183 EC EMC ...
Page 197: ...EXTERNAL PRESET VLT 5000 Series 194 MG 51 C5 22 VLT p is a registered Danfoss trademark ...
Page 202: ...VLT 5000 Series MG 51 C5 22 VLT p is a registered Danfoss trademark 199 List of functions ...
Page 217: ...VLT 5000 Series 214 MG 51 C5 22 VLT p is a registered Danfoss trademark ...
Page 239: ......