LCP procedure for entering text
After selecting
Display Text
in parameter 009 and 010,
select display line parameter (553 or 554) and press
the
CHANGE DATA
key. Enter text directly into the
selected line by using
UP, DN & LEFT, RIGHT
arrow
keys on the LCP. The UP and DN arrow keys scroll
through the available characters. The Left and Right
arrow keys move the cursor through the line of text.
To lock in the text, press the
OK
key when the line of
text is completed. The
CANCEL
key will cancel the
text.
The available characters are:
A B C D E F G H I J K L M N O P Q R S T U V W X Y
Z Æ Ø Å Ä Ö Ü É Ì Ù è . / - ( ) 0 1 2 3 4 5 6 7 8 9 'space'
'space' is the default value of parameter 553 & 554. To
erase a character that has been entered, it must be
replaced with 'space'.
553
Display text 1
(DISPLAY TEXT ARRAY 1)
Value:
Max. 20 charac-
ters
[XXXXXXXXXXXXXXXXXXXX]
Function:
Here, a text of max. 20 characters can be written that
will be shown in display line 1, provided
LCP display
text
[27] has been selected in parameter
010 Display
line 1.1
. Example of display text:
175ZA792.10
VLT NO.8
SETUP
1
CLEANING SYSTEM NO.2
AUTO REMOTE RUNNING
Description of choice:
The required text can be written via serial communi-
cation or by means of the arrow keypads on the LCP.
554
Display text 2
(DISPLAY TEXT ARRAY 2)
Value:
Max. 8 characters
[XXXXXXXX]
Function:
Here, a text of max. 8 characters can be written that
will be shown in display line 2, provided
LCP Display
Text
[29] has been selected in parameter 009
Display
line 2
Description of choice:
The required text can be written via serial communi-
cation or by means of the arrow keypads on the LCP.
580–582 Defined parameters
(DEFINED PARAM.)
Value:
Read only
Function:
The three parameters contain a list of all parameters
defined in the VLT. Each parameter contains up to 116
elements (parameter numbers). The number of pa-
rameters that are in use (580, 581, 582) depends on
the respective VLT configuration. When a 0 is used as
a parameter number, the list ends.
Description of choice:
VLT
®
5000 Series
= factory setting, () = display text, [] = value for use in communication via serial communication port
148
MG.51.C5.22 - VLT
p
is a registered Danfoss trademark.
Summary of Contents for VLT 5000 Series
Page 2: ...VLT 5000 Instruction Manual ...
Page 3: ......
Page 185: ...VLT 5000 Series 182 MG 51 C5 22 VLT p is a registered Danfoss trademark ...
Page 186: ...VLT 5000 Series MG 51 C5 22 VLT p is a registered Danfoss trademark 183 EC EMC ...
Page 197: ...EXTERNAL PRESET VLT 5000 Series 194 MG 51 C5 22 VLT p is a registered Danfoss trademark ...
Page 202: ...VLT 5000 Series MG 51 C5 22 VLT p is a registered Danfoss trademark 199 List of functions ...
Page 217: ...VLT 5000 Series 214 MG 51 C5 22 VLT p is a registered Danfoss trademark ...
Page 239: ......