PNU
Parameter
Factory setting Range
Changes
4-Set-up
Conver-
sion
Data
#
description
during operation
index
type
500
Address
1
0 - 126
Yes
No.
0
6
501
Baud rate
9600 baud
Yes
No.
0
5
502
Coasting
Logic or
Yes
Yes
0
5
503
Quick stop
Logic or
Yes
Yes
0
5
504
DC-brake
Logic or
Yes
Yes
0
5
505
Start
Logic or
Yes
Yes
0
5
506
Reversing
Logic or
Yes
Yes
0
5
507
Selection of set-up
Logic or
Yes
Yes
0
5
508
Selection of speed
Logic or
Yes
Yes
0
5
509
Bus jog 1
10.0 Hz
0.0 - parameter 202
Yes
Yes
-1
6
510
Bus jog 2
10.0 Hz
0.0 - parameter 202
Yes
Yes
-1
6
511
512
Telegram profile
FC Drive
No.
Yes
0
5
513
Bus time interval
1 sec
1 - 99 s
Yes
Yes
0
5
514
Bus time interval function
Off
Yes
Yes
0
5
515
Data readout: Reference %
No.
No.
-1
3
516
Data readout: Reference unit
No.
No.
-3
4
517
Data readout: Feedback
No.
No.
-3
4
518
Data readout: Frequency
No.
No.
-1
6
519
Data readout: Frequency x Scaling
No.
No.
-2
7
520
Data readout: Current
No.
No.
-2
7
521
Data readout: Torque
No.
No.
-1
3
522
Data readout: Power, kW
No.
No.
1
7
523
Data readout: Power, HP
No.
No.
-2
7
524
Data readout: Motor voltage
No.
No.
-1
6
525
Data readout: DC link voltage
No.
No.
0
6
526
Data readout: Motor temp.
No.
No.
0
5
527
Data readout: VLT temp.
No.
No.
0
5
528
Data readout: Digital input
No.
No.
0
5
529
Data readout: Terminal 53,
analog input
No.
No.
-2
3
530
Data readout: Terminal 54,
analog input
No.
No.
-2
3
531
Data readout: Terminal 60,
analog input
No.
No.
-5
3
532
Data readout: Pulse reference
No.
No.
-1
7
533
Data readout: External reference %
No.
No.
-1
3
534
Data readout: Status word, binary
No.
No.
0
6
535
Data readout: Braking energy/2 min.
No.
No.
2
6
536
Data readout: braking energy/sec
No.
No.
2
6
537
Data readout: Heatsink temperature
No.
No.
0
5
538
Data readout: Alarm word, binary
No.
No.
0
7
539
Data readout: VLT Control word, binary
No.
No.
0
6
540
Data readout: Warning word, 1
No.
No.
0
7
541
Data readout: Extended Status word
No.
No.
0
7
553
Display text 1
No.
No.
0
9
554
Display text 2
No.
No.
0
9
557
Data readout: Motor RPM
No.
No.
0
4
558
Data readout: Motor RPM x scaling
No.
No.
-2
4
580
Defined parameter
No.
No.
0
6
581
Defined parameter
No.
No.
0
6
582
Defined parameter
No.
No.
0
6
VLT
®
5000 Series
226
MG.51.C5.22 - VLT
p
is a registered Danfoss trademark.
Summary of Contents for VLT 5000 Series
Page 2: ...VLT 5000 Instruction Manual ...
Page 3: ......
Page 185: ...VLT 5000 Series 182 MG 51 C5 22 VLT p is a registered Danfoss trademark ...
Page 186: ...VLT 5000 Series MG 51 C5 22 VLT p is a registered Danfoss trademark 183 EC EMC ...
Page 197: ...EXTERNAL PRESET VLT 5000 Series 194 MG 51 C5 22 VLT p is a registered Danfoss trademark ...
Page 202: ...VLT 5000 Series MG 51 C5 22 VLT p is a registered Danfoss trademark 199 List of functions ...
Page 217: ...VLT 5000 Series 214 MG 51 C5 22 VLT p is a registered Danfoss trademark ...
Page 239: ......