69
4.4.2 Color Controller C-80 Turns On, No Operating System
In this situation it is not possible to run the JOIND diagnostics software.
4.4.3 Color Controller C-80 Does Not Execute Commands
In this situation it is possible to run the JOIND diagnostics software.
Symptom
Recovery Action
The operating
system does
not initialize.
Verify the following:
•
The SATA2 cables and the power cables are
properly connected.
•
The system disk is not damaged physically.
•
The boot order is correct.
To verify the boot order:
1. Restart the server.
2. Press
DELETE
to enter the computer BIOS.
3. Use the arrow keys to select the
Boot
menu.
4. Verify the boot order is the same as shown in step
5. Reload the operating system; see page 39.
6. Replace the system disk.
Symptom
Recovery Action
The FusionRA board
does not appear when
running diagnostics.
1. Verify that the FusionRA board is correctly
seated.
2. Replace the input memory located on the
FusionRA board.
3. Replace the FusionRA board.
A disk is not
functioning properly.
1. Check that the disk is correctly installed.
2. Verify that each SATA2 cable is connected
to the correct disk and system board
connector.
3. Verify that the voltage cable to each disk is
securely connected.
Several tests fail as a
result of a particular
failure.
When there is a memory failure replace the
Fusion RA board and run tests on the board
again.
Summary of Contents for Color Controller C-80
Page 2: ......
Page 8: ...vi Color Controller C 80 1 0 Technical Manual...
Page 17: ...1 Product Overview Introduction 2 Product Configuration 4...
Page 22: ...6 Chapter 1 Product Overview...
Page 52: ...36 Chapter 2 First Time Setup and Configuration...
Page 103: ...87 5 Click Yes 6 Click OK 7 To enable the changes to take effect restart your computer...
Page 104: ...88 Chapter 4 Diagnostics and Troubleshooting...
Page 142: ...126 Chapter 5 Hardware and Maintenance Repairs...
Page 149: ......
Page 150: ......