background image

USER MANUAL

AUGUST 2016

MM102

Red wire

5V positive

power supply

Black wire

GND negative

power supply

Yellow wire

Humidity output /

data request

ANALOG HUMIDITY SENSOR BOARD

This breakout board is equipped with a hygrometric sensor, thus 

it lends itself to detect the moisture found in the environment it is 

placed in. It operates at a very low voltage (it correctly operates at 

up to 5.5 Vcc) and typically absorbs 200 microamperes: it is thus 

ideal even in applications that are battery powered, and in which a 

minimal absorption is required.

The HIH-5030-001 sensor has the great virtue of supplying an 

analog output signal, consisting in a DC voltage that varies in an 

almost linear manner, as the relative humidity (RH) varies; thus it 

may be interfaced both to analog circuits that check the air flow of 

a dehumidifier installation, and it may be read by an A/D converter 

or by a microcontroller’s input that is supplied with an analog/digital 

converter. 

The device’s sensor component is of the capacitive kind, and it is 

composed of thermosetting polymers that have been cut with a la-

ser. The signal’s conditioning circuitry, integrated on a chip, is found in 

the integrated circuit. The multilayer construction of the sensitive ele-

ment provides an excellent resistance to the greatest part of the risks 

coming from applications such as, for example, condensation, dust, 

filth, oils and common chemical products found in the measurement 

environment.