GR716-DS-UM, May 2019, Version 1.29
88
www.cobham.com/gaisler
GR716
Table 68.
0x00 - CFG - Reset Generation and Brownout Detection Configuration register
31
21 20
18 17
15 14
12 11
9
8
6
5
3
2
0
R
BLI
BLC
BLA
BLD
BLB
BLL
BLP
0
b000
b000
b000
b000
b000
b000
b000
rw
rw
rw
rw
rw
rw
rw
31: 21
Reserved
20: 18
Brown Out Level for 3.3 V power supply (BLI)
17: 15
Brown Out Level for 1.8 V power supply (BLC)
14: 12
Brown Out Level for Analog ADC supply (BLA)
11: 9
Brown Out Level for Analog DAC supply (BLD)
8: 6
Brown Out Level for BandGap supply (BLB)
5: 3
Brown Out Level for LVDS power supply (BLL)
2: 0
Brown Out Level for PLL power supply (BLP)
000 sets the minimum value for the threshold, 111 the maximum
Table 69.
0x04 - STS - Reset Generation and Brownout Detection status register
31
6
5
4
3
2
1
0
RESERVED
BI BC BA BD BB BL BP
0x00000000
0
0
0
0
0
0
0
r
r
r
r
r
r
r
r
31: 7
RESERVED
6
Brown Out Detected (BI) - Faulty 3.3 V power supply detected
5
Brown Out Detected (BC) - Faulty 1.8 V power supply detected
4
Brown Out Detected (BA) - Faulty ADC power supply
3
Brown Out Detected (BD) - Faulty DAC power supply
2
Brown Out Detected (BB) - Faulty BandGap power supply
1
Brown Out Detected (BL) - Faulty LVDS power supply detected
0
Brown Out Detected (BP) - Faulty PLL power supply detected
Table 70.
0x08 - IRQ - Reset Generation and Brownout Detection Interrupt Flags
31
6
5
4
3
2
1
0
RESERVED
II
IB ID IA IC IL IR
0x00000000
0
0
0
0
0
0
0
r
wc wc wc wc wc wc wc
31: 7
RESERVED
6
Interrupt Flag for Brown Out Detection (II)
5
Interrupt Flag for Brown Out Detection (IC)
4
Interrupt Flag for Brown Out Detection (IA)
3
Interrupt Flag for Brown Out Detection (ID)
2
Interrupt Flag for Brown Out Detection (IB)
1
Interrupt Flag for Brown Out Detection (IL)
0
Interrupt Flag for Brown Out Detection (IP)