GR716-DS-UM, May 2019, Version 1.29
111
www.cobham.com/gaisler
GR716
31:19
RESERVED
18:0
ADC High Level detection threshold (AHT) - An interrupt shall be generated if the sampled value is above the
specified value in this register
Table 103.
0x24 - ALT -ADC Low Level detection register
31
19 18
0
Reserved
ALT
0
-
r
rw
31:19
RESERVED
18:0
ADC Low Level detection threshold (ALT) - An interrupt shall be generated if the sampled value is below the
specified value in this register
Note:
To make use of this function the AD C must be enable the ACFG.AH bit must set
Table 104.
0x2C - 0x38 - ASQ - ADC Sequence status register 0,1,2 and 3
31
19 18
0
Reserved
AD
0
-
r
rw
31:19
RESERVED
18:0
ADC digital output (AD) - Digital sampled value. The number of samples accumulated is determined by the
number of samples defined in the ASAMPC register. Reading a register with a higher index can cause the read-
ing of an old value from previous sequences of events.
Note:
To make use of this function the AD C must be enable the ACFG.AL bit must set
Note2:
There are 4 individual status registers
Table 102.
0x20 - AHT -ADC High Level detection register