GR716-DS-UM, May 2019, Version 1.29
359
www.cobham.com/gaisler
GR716
34.6.23
Table 463.
0x070 - TR3 - Time Stamp Elapsed Time 3 Rx
Time Stamp Elapsed Time 3 Rx
34.6.24
Table 464.
0x074 - TR4 - Time Stamp Elapsed Time 4 Rx
Time Stamp Elapsed Time 4 Rx
34.6.25
Table 465.
0x080 - TTPFTx - Time-Stamp SpaceWire Time-Code and Preamble Field Tx
Time-Stamp SpaceWire Time-Code and Pramble Field Tx
34.6.26
Table 466.
0x084 - TT0 - Time Stamp Elapsed Time 0 Tx
Time Stamp Elapsed Time 0 Tx
31
0
TR3
0
r
31: 0
TR3
Time stamped local ET value (96 to 127) when distributed interrupt received.
31
24 23
0
TR4
RESERVED
0
0
r
r
31: 24
TR4
Time stamped local ET value (128 to 135) when distributed interrupt received.
23: 0
RESERVED
31
24 23
16 15
0
TSTC
RESERVED
TTPF
0
0
0x2800
rw
r
r
31: 24
TSTC
Time stamp time code
Time stamp on this time-code value, used for time stamping when this register
matched with SpaceWire Time-Codes
.
The mask for this matching is available in
configuration register 3. (only for initiator)
23: 16
RESERVED
15: 0
TTPF
Time stamp Preamble Field
The number of coarse and fine time implemented can be obtained from this Pre-
amble Field.
31
0
TT0
0
r
31: 0
TT0
Time stamped local ET value (0 to 31) when distributed interrupt transmitted.