GR716-DS-UM, May 2019, Version 1.29
321
www.cobham.com/gaisler
GR716
31: 0
Reply address (RA) - Shows byte 0-3 of the Reply Address from the last successful compare-and-swap com-
mand that set to the Device ID field. If there was no Reply Address, then this field is zero.
Table 383.
0x00000006 - PNPOA1 - SpaceWire Plug-and-Play - Owner Address 1
31
0
RA
0x00000000
r
31: 0
Reply address (RA) - Shows byte 4-7 of the Reply Address from the last successful compare-and-swap com-
mand that set to the Device ID field. If the Reply Address was four bytes or less, then this field is zero.
Table 384.
0x00000007 - PNPOA2 - SpaceWire Plug-and-Play - Owner Address 2
31
0
RA
0x00000000
r
31: 0
Reply address (RA) - Shows byte 8-11 of the Reply Address from the last successful compare-and-swap com-
mand that set to the Device ID field. If the Reply Address was eight bytes or less, then this field is zero.
Table 385.
0x00000008 - PNPDEVID - SpaceWire Plug-and-Play - Device ID
31
0
DID
0x00000000
cas
31: 0
Device ID (DID) - Shows the device identifier. This field is set to zero after reset / power-up, and when the link-
interface is not in run-state.
Table 386.
0x00000009 - PNPUVEND - SpaceWire Plug-and-Play - Unit Vendor and Product ID
31
16 15
0
VEND
PROD
*
*
r
r
31: 16
Unit vendor ID (VEND) - Shows the unit vendor identifier. This field is read-only through the SpaceWire Plug-
and-Play protocol, however it is writable through an APB register (see section 33.11). Reset value is taken from
the input signal PNPUVENDID
.
Whenever this field, or the PROD field, is set to a non-zero value, the
PNPLINFO.U bit is set to 1.
15: 0
Unit product ID (PROD) - Shows the unit product identifier. This field is read-only through the SpaceWire Plug-
and-Play protocol, however it is writable through an APB register (see section 33.11). Reset value is taken from
the input signal PNPUPRODID
.
Whenever this field, or the VEND field, is set to a non-zero value, the
PNPLINFO.U bit is set to 1.
Table 387.
0x0000000A - PNPUSN - SpaceWire Plug-and-Play - Unit Serial Number
31
0
USN
*
r
31: 0
Unit serial number (USN) - Shows the unit serial number. This field is read-only through the SpaceWire Plug-
and-Play protocol, however it is writable through the APB register (see section 33.11). Reset value is taken from
the input signal PNPUSN.
Table 382.
0x00000005 - PNPOA0 - SpaceWire Plug-and-Play - Owner Address 0