GR716-DS-UM, May 2019, Version 1.29
547
www.cobham.com/gaisler
GR716
55
Errata
This chapter describes known issues with current existing silicon.
If not otherwise stated, the items in this section are planned for correction in the next revision of the
silicon.
For more information contact [email protected].
55.1
Overview
Table 719 lists errata that are further described in section 55.2.
55.2
Errata description
55.2.1 XO doesn't start to oscillate due to low gain
ID
: GR716-ERRATA-20190401
The drive strength of the XO have small gain margin compared to what is needed in-order to start
oscillation of a external crystal. The impact is that the crystal and its passive components needs to be
chosen carefully to guarantee that the oscillator is starting successfully. Frequency, load capacitance
and ESR value needs to be considered. Refer to the XO section for suggested crystals.
Workaround
: N/A
This item is planned to be corrected for the next revision of the silicon.
55.2.2 VMON erroneous startup state
ID
: GR716-ERRATA-20190402
The Brown out blocks could start in a triggered and latched state after power-on. One feature of the
brown out is that it locks the IOs direction when it triggers. This together with the faulty state after
power on implies that the supported boot alternatives are limited. IO direction is only locked for
GR716-XX-CQ132-AAAA.
Workaround
: To get to a known state after power-on toggle the power down signals to each of the
brown out blocks. First set the signals to logic high, followed by logic low. After this sequence the
brown out is in a known state and will work as intended.
Table 719.
Errata
ID
Device(s) Affected
Name / Description
GR716-ERRATA-20190401
GR716-XX-CQ132-AAAA
GR716-XX-CQ132-AAAB
XO doesn't start to oscillate due to low gain
GR716-ERRATA-20190402
GR716-XX-CQ132-AAAA
GR716-XX-CQ132-AAAB
VMON erroneous startup state
GR716-ERRATA-20190403
GR716-XX-CQ132-AAAA
GR716-XX-CQ132-AAAB
Internal ADC settling time is too short
GR716-ERRATA-20190404
GR716-XX-CQ132-AAAA
GR716-XX-CQ132-AAAB
ADC offset error
GR716-ERRATA-20190405
GR716-XX-CQ132-AAAA
GR716-XX-CQ132-AAAB
FTMCTRL external PROM chip select anomaly for 8 MiB
bank size
GR716-ERRATA-20190406
GR716-XX-CQ132-AAAA
GR716-XX-CQ132-AAAB
GRDMAC channels must be in ascending order without
spaces
GR716-ERRATA-20190506
GR716-XX-CQ132-AAAA
GR716-XX-CQ132-AAAB
PLL does not lock for high frequency input
GR716-ERRATA-20190507
GR716-XX-CQ132-AAAA
GR716-XX-CQ132-AAAB
ADC Pre-amplifier Gain non-ideal