Chapter 5 - Parameter List
5-4
Keypad Display
Setting Range
Code
Description
LCD
7-Segment
LCD
7-Segment
Units
Factory
Default
Adj.
During
Run
Page
FU1-25
High Limit Frequency
F-limit Hi
25
FU1-24 to FU1-20
0.01 60.00 [Hz]
No
Manual 0
FU1-26
Manual/Auto Torque
Boost Selection
Torque boost
26
Auto 1
- Manual No
6-2
FU1-27
Torque Boost in Forward
Direction
Fwd boost
27
0 to 15 [%]
0.1
2.0 [%]
No
FU1-28
Torque Boost in Reverse
Direction
Rev boost
28
0 to 15 [%]
0.1
2.0 [%]
No
6-2
Linear 0
Square 1
FU1-29
Volts/Hz Pattern
V/F pattern
29
User V/F
2
- Linear No
6-2
FU1-30
15
User V/F – Frequency 1
User freq 1
30
0 to FU1-20
0.01 15.00 [Hz]
No
FU1-31
User V/F – Voltage 1
User volt 1
31
0 to 100 [%]
1
25 [%]
No
FU1-32
User V/F – Frequency 2
User freq 2
32
0 to FU1-20
0.01 30.00 [Hz]
No
FU1-33
User V/F – Voltage 2
User volt 2
33
0 to 100 [%]
1
50 [%]
No
FU1-34
User V/F – Frequency 3
User freq 3
34
0 to FU1-20
0.01 45.00 [Hz]
No
FU1-35
User V/F – Voltage 3
User volt 3
35
0 to 100 [%]
1
75 [%]
No
FU1-36
User V/F – Frequency 4
User freq 4
36
0 to FU1-20
0.01 60.00 [Hz]
No
FU1-37
User V/F – Voltage 4
User volt 4
37
0 to 100 [%]
1
100 [%]
No
6-2
FU1-38
Output Voltage
Adjustment
Volt control
38
40 to 110 [%]
0.1
100.0 [%]
No
6-2
FU1-39
Energy Save Level
Energy save
39
0 to 30 [%]
1
0 [%]
Yes
6-2
No 0
FU1-50
Electronic Thermal
Selection
ETH select
50
Yes 1
- No Yes
FU1-51
16
Electronic Thermal Level
for 1 Minute
ETH 1 min
51
FU1-52 to 200 [%]
1
150 [%]
Yes
FU1-52
Electronic Thermal Level
for Continuous
ETH cont
52
50 to FU1-51
1
100 [%]
Yes
Self-cool 0
FU1-53
Electronic Thermal
Characteristic Selection
(Motor Type)
Motor type
53
Forced-cool 1
- Self-cool Yes
6-2
FU1-54
Overload Warning Level
OL level
54
30 to 150 [%]
1
150 [%]
Yes
FU1-55
Overload Warning Hold
Time
OL time
55
0 to 30 [sec]
0.1
10.0 [sec]
Yes
6-2
No 0
FU1-56
Overload Trip Selection
OLT select
56
Yes 1
- Yes Yes
FU1-57
Overload Trip Level
OLT level
57
30 to 150 [%]
1
180 [%]
Yes
FU1-58
Overload Trip Delay Time
OLT time
58
0 to 60 [sec]
1
60.0 [sec]
Yes
6-2
FU1-59
Stall Prevention Mode
Selection
Stall prev.
59
000 to 111
(Bit Set)
bit 000 No
FU1-60
Stall Prevention Level
Stall level
60
30 to 250 [%]
1
180 [%]
No
6-2
15
Code FU1-30 through FU1-37 appears only when FU1-29 is set to ‘User V/F’.
16
Code FU1-51 through FU1-53 appears only when FU1-50 is set to ‘Yes’.
Summary of Contents for 30 HP30
Page 6: ......
Page 12: ......
Page 16: ...Chapter 1 Installation 1 4 BLANK ...
Page 18: ...Chapter 1 Installation 1 6 BLANK ...
Page 28: ...Chapter 1 Installation 1 16 Notes ...
Page 39: ...Chapter 2 Operation 2 11 Notes ...
Page 40: ......
Page 46: ......
Page 60: ...Chapter 4 Operation Examples 4 14 Notes ...
Page 83: ...Chapter 5 Parameter List 5 23 Notes ...
Page 84: ......
Page 92: ...Chapter 6 Parameter Description DRV 6 8 Notes ...
Page 105: ......
Page 106: ...Chapter 6 Parameter description FU1 6 14 Notes ...
Page 126: ...Chapter 6 Parameter Description FU2 6 34 Notes ...
Page 144: ...Chapter 6 Parameter Description I O 6 52 Notes ...
Page 162: ......
Page 188: ...Chapter 7 Options 7 26 Type 1 Max 400 Watt Type 2 Max 600 Watt A ...
Page 189: ...Chapter 7 Options 7 27 Type 3 ...
Page 194: ......
Page 204: ......
Page 210: ......