Chapter 1 - Installation
1-12
Wires and Terminal Lugs
Refer to the following table for wires, terminal lugs, and screws used to connect the inverter power input
(R, S, T) and output (U, V, W).
Wire
9
Ring Terminals
mm
²
AWG
Inverter Capacity
Terminal
Screw Size
Screw
Torque
8
(Kgf·cm)/lb-in
R,S,T
U,V,W
R,S,T
U,V,W
R,S,T
U,V,W
1 ~ 3 HP
M3.5
15 / 10
2-4
2-4
2
2
14
14
5 HP
M3.5
15 / 10
2-4
2-4
3.5
3.5
12
12
7.5 HP
M4
15 / 10
5.5-5
5.5-5
5.5
5.5
10
10
10 HP
M4
15 / 10
14-5
8-5
14
8
6
8
15 HP
M5
26 / 18
14-5
14-5
14
14
6
6
20 HP
M5
26 / 18
22-6
22-6
22
22
4
4
25 HP
M6
45 / 31
38-8
38-8
30
30
2
2
200V
Class
30 HP
M6
45 / 31
38-8
38-8
38
30
2
2
1 ~ 5 HP
M3.5
15 / 10
2-4
2-4
2
2
14
14
7.5 HP
M4
15 / 10
5.5-5
5.5-5
3.5
2
12
14
10 HP
M4
15 / 10
14-5
8-5
3.5
3.5
12
12
15 HP
M5
26 / 18
14-5
14-5
5.5
5.5
10
10
20 HP
M5
26 / 18
22-6
22-6
14
8
6
8
25 HP
M6
45 / 31
38-8
38-8
14
8
6
8
400V
Class
30 HP
M6
45 / 31
38-8
38-8
22
14
4
6
Power and Motor Connection
R S T G N B1 B2 U V W
8
Apply the rated torque to terminal screws. Loose screws can cause of short circuit or malfunction. Tightening the screws too much can
damage the terminals and cause a short circuit or malfunction.
9
Use copper wires only with 600V, 75
℃
ratings.
Motor
3 Phase
Power Input
Power supply must be connected
to the R, S, and T terminals.
Connecting it to the U, V, and W
terminals causes internal damages
to the inverter. Arranging the phase
sequence is not necessary.
Motor should be connected to the
U, V, and W terminals.
If the forward command (FX) is on,
the motor should rotate counter
clockwise when viewed from the load
side of the motor. If the motor rotates
in the reverse, switch the U and V
terminals.
Summary of Contents for 30 HP30
Page 6: ......
Page 12: ......
Page 16: ...Chapter 1 Installation 1 4 BLANK ...
Page 18: ...Chapter 1 Installation 1 6 BLANK ...
Page 28: ...Chapter 1 Installation 1 16 Notes ...
Page 39: ...Chapter 2 Operation 2 11 Notes ...
Page 40: ......
Page 46: ......
Page 60: ...Chapter 4 Operation Examples 4 14 Notes ...
Page 83: ...Chapter 5 Parameter List 5 23 Notes ...
Page 84: ......
Page 92: ...Chapter 6 Parameter Description DRV 6 8 Notes ...
Page 105: ......
Page 106: ...Chapter 6 Parameter description FU1 6 14 Notes ...
Page 126: ...Chapter 6 Parameter Description FU2 6 34 Notes ...
Page 144: ...Chapter 6 Parameter Description I O 6 52 Notes ...
Page 162: ......
Page 188: ...Chapter 7 Options 7 26 Type 1 Max 400 Watt Type 2 Max 600 Watt A ...
Page 189: ...Chapter 7 Options 7 27 Type 3 ...
Page 194: ......
Page 204: ......
Page 210: ......