![CMC 30 HP30 Installation And Operation Instruction Manual Download Page 59](http://html.mh-extra.com/html/cmc/30-hp30/30-hp30_installation-and-operation-instruction-manual_2627175059.webp)
Chapter 4 - Operation Examples
4-13
Operation
Example (5)
Vector_SPD Control
[Operation condition]
-. Control Mode : Vector_SPD Control, -. Encoder specification : Pulse number (1024), Line Drive type
-. Freq command : set it 55[Hz] via KPD-1
-. Accel/Decel time : Accel – 15 [sec], Decel – 25 [sec], -. Drive mode : Run/Stop via terminal FX/RX
[Wiring]
AOC
R
S
T
G
U
V
W
B1
B2
FX
RX
BX
RST
JOG
P1
P2
P3
CM
VR
V1
5G
IM
3P
AC
Input
BOC
A+
A-
B+
B-
FBA
FBB
GND
E
Encoder
GND
+5V
+5V
VCC
VCC
Keypad
connector
MODE
PROG
ENT
REV
SHIFT
ESC
STOP
RESET
FWD
LC-200
Sub-B
Step
Parameter setting
Code
Description
1 Motor
related
setting
FU2-30 ~ FU2-
36
Set motor capacity, pole number, rated voltage/ current/slip and
efficiency.
2 Encoder
related
setting
EXT-12
EXT-15
EXT-16
Set EXT-12 to Feed-back, EXT-1 to A+B
Set EXT-16 to 1024
3
Control Mode Selection
Fu2-39
Encoder related setting should be done before setting control mode to
Vector_SPD.
4 Auto-tuning
FU2-40
Auto-tuning starts when set to ALL. Read the encode rmanual carefully
to clear the error if the messages ” Enc Err”, “Enc Rev” are displayed.
5
Keypad input setting
DRV-4
DRV-0
Set DRV-4 to KPD-1 and press the Prog key to set 55 [Hz] in Drv-0.
6
Accel/Decel time setting
DRV-1
DRV-2
Accel time: set 15[Sec]
Decel time: set 25[Sec]
7
Drive mode
DRV-3
Set it to FX/RX-1.
8 FX/RX
terminal
Motor runs with Accel time 15 [Sec] at 55 [Hz] if FX/RX terminal is
turned ON.
Motor decelerates to stop with Decel time 25 [Sec] if FX/RX terminal is
turned OFF.
Summary of Contents for 30 HP30
Page 6: ......
Page 12: ......
Page 16: ...Chapter 1 Installation 1 4 BLANK ...
Page 18: ...Chapter 1 Installation 1 6 BLANK ...
Page 28: ...Chapter 1 Installation 1 16 Notes ...
Page 39: ...Chapter 2 Operation 2 11 Notes ...
Page 40: ......
Page 46: ......
Page 60: ...Chapter 4 Operation Examples 4 14 Notes ...
Page 83: ...Chapter 5 Parameter List 5 23 Notes ...
Page 84: ......
Page 92: ...Chapter 6 Parameter Description DRV 6 8 Notes ...
Page 105: ......
Page 106: ...Chapter 6 Parameter description FU1 6 14 Notes ...
Page 126: ...Chapter 6 Parameter Description FU2 6 34 Notes ...
Page 144: ...Chapter 6 Parameter Description I O 6 52 Notes ...
Page 162: ......
Page 188: ...Chapter 7 Options 7 26 Type 1 Max 400 Watt Type 2 Max 600 Watt A ...
Page 189: ...Chapter 7 Options 7 27 Type 3 ...
Page 194: ......
Page 204: ......
Page 210: ......