A-3
Cisco BPX 8600 Series Installation and Configuration
Release 9.3.30, Part Number 78-12907-01 Rev. E0, May 2005
Appendix A Upgrade Information
Upgrade Options
Upgrade Options
Use one of the following upgrade options described in Table A-2:
Table A-2
Upgrade Options
Option
Used when...
Steps
Y-Red BXMs,
manual
Legacy BXMs are Y-red
and the “auto BXM
upgrade parameter” is
set to “N” for the
cnfnodeparm
command.
1.
Remove the standby BXM card and replace it with the BXM-E card.
2.
BXM-E card scan be flagged as “Mismatch” if the configured channel
statistics level or number of connections is smaller than those configured on
the active BXM card. Use the command
cnfcdparm
<BXM-E slot_num> to
configure the desired level of channel statistics and number of connections,
if not already configured. The BXM-E card is reset after the
cnfcdparm
command is executed. After the BXM-E card boots, there should be no
mismatch.
3.
Y-red the switch so that the standby BXM-E becomes active.
4.
Repeat steps 1-2 for the other slot.
You still can fall back to the legacy card
up to this point.
5.
Upgrade the logical card using the command
upgdlogcd
<log_card_num>.
Switch software upgrades the logical database from the number of
connections configured on the legacy BXM card to the number of
connections configured in step 2 and 4. From this point on, mismatch is
declared if the legacy card is reinserted.
Note
During upgrading Y-red BXM cards to BXM-E cards, the level of service
disruption is expected to be the same as the one experienced when
switchyred
is executed for Y-red legacy BXMs.
Y-red BXMs,
automatic
Legacy BXMs are Y-red
and the “auto BXM
upgrade” parameter is
set to Y for the
cnfnodeparm
command.
1.
Remove the standby BXM card and replace it with the BXM-E card.
2.
BXM-E card can be flagged as ‘Mismatch’ if the configured channel
statistics level or number of connections is smaller than those configured on
the active BXM card. Use the command
cnfcdparm
<BXM-E slot_num> to
configure the desired level of channel statistics and number of connections,
if not already configured. The BXM-E card is reset after the
cnfcdparm
command is executed. After the BXM-E card boots, there should be no
mismatch.
3.
Y-red the switch so that the standby BXM-E becomes active.
4.
Repeat steps 1and 2 for the other slot.
5.
Switch software automatically upgrades the logical database when step 4 is
done.
Note
During upgrading Y-red BXM cards to BXM-E cards, the level of service
disruption is expected to be the same as the one experienced when
switchyred
is executed for Y-red legacy BXMs.
Summary of Contents for BPX 8650
Page 49: ...P A R T 1 The BPX Switch ...
Page 50: ......
Page 159: ...P A R T 2 Installation ...
Page 160: ......
Page 273: ...P A R T 3 Initial Configuration and Network Management ...
Page 274: ......
Page 311: ...P A R T 4 Configuring Connections ...
Page 312: ......
Page 487: ...P A R T 5 Troubleshooting and Maintenance ...
Page 488: ......
Page 533: ...P A R T 6 BPX Specifications ...
Page 534: ......
Page 555: ...P A R T 7 Appendices ...
Page 556: ......