BPX Switch Cabling Summary
This chapter specifies the cabling required to install the BPX switch.
Contents of this chapter include:
•
•
•
•
•
•
Note
In all cable references:
The Transmit direction is
from
the BPX switch.
The Receive direction is
to
the BPX switch.
Trunk Cabling
Trunk cables connect the customer DSX-3 crossconnect point or T3-E3 Interface Module to the BPX
switch at the LM-3T3 back card (see Table 31-1).
Table 31-1
Trunk Cables
Cable Parameter
Description
Type:
75-ohm coax cable (RG-59 B/U for short runs, AT&T 734A for longer runs). Two
per T3/E3 line (XMT and RCV).
For European shipment of the BXM-E3 cards, in order to meet CE mark transient
test requirement (IEC1000-4-4), RG-17G double shielded SMB cable must be
used.
Max. Length:
450 feet max. between the BPX switch and the DSX-3/E3 point.
Connector:
Terminated in male BNC; Rx is receive from trunk, Tx is transmit to trunk.