30-6
Cisco BPX 8600 Series Installation and Configuration
Release 9.3.30, Part Number 78-12907-01 Rev. E0, May 2005
Chapter 30 BPX Node Specifications
ATM OC3 Trunk Interface (BNI-OC3, LM-OC3)
ATM OC3 Trunk Interface (BNI-OC3, LM-OC3)
Barrier:
Fully barriered per EN 41003
ATM Cell Rate:
80,000 cells/sec
Jitter:
per CCITT G.823
ATM Layer Protocol:
per CCITT I.361 with HEC
Port Alarm Processing:
AIS
Loss of Signal
Remote Alarm Indication
Loss of Framing
Line Errors Counted:
BPV
Parity Bit Errors
Connector:
75 ohm BNC
Max. E3 Cable Lengths:
100 meters. Cabling must not exceed -6 dB/1000 feet at E3 rates.
Cisco supplies cable with a maximum attenuation of 7 dB/1000
feet, but the maximum cable length must not exceed 100 meters.
Indicators:
Card status
Port status
Line Rate:
155.52 Mbps
Line Code:
NRZ
Signal Level:
Max
Min
MMF TX
–8 dBm
–15 dBm
MMF RX
–8 dBm
–28 dBm
SMF LR TX
0 dBm
–5 dBM
SMF LR RX
–10 dBm
–34 dBm
Framing Format:
STS-3c, STM1
Port Interface:
LMI, ILMI
ATM Cell Rate:
353,208 cells/sec.
Jitter:
< 0.1 UI p-p, < 0.01 UI rms
Summary of Contents for BPX 8650
Page 49: ...P A R T 1 The BPX Switch ...
Page 50: ......
Page 159: ...P A R T 2 Installation ...
Page 160: ......
Page 273: ...P A R T 3 Initial Configuration and Network Management ...
Page 274: ......
Page 311: ...P A R T 4 Configuring Connections ...
Page 312: ......
Page 487: ...P A R T 5 Troubleshooting and Maintenance ...
Page 488: ......
Page 533: ...P A R T 6 BPX Specifications ...
Page 534: ......
Page 555: ...P A R T 7 Appendices ...
Page 556: ......