13-13
Cisco BPX 8600 Series Installation and Configuration
Release 9.3.30, Part Number 78-12907-01 Rev. E0, May 2005
Chapter 13 Installing the BPX Switch Cards
Installation of APS Redundant Frame Assembly and Back Cards
Figure 13-9 APS 1:1 Redundancy
APS 1+1 Redundancy Installation
APS 1+1 redundancy provides both card and line redundancy. It uses the standard BXM OC-3 and
OC-12 front cards but requires a special APS Redundant Backplane and APS Redundant back cards.
With previous card cages, because of the positioning of mechanical dividers, the APS card pairs could
be inserted only in slots 2 through 5 and 10 through 13. The mechanical dividers are located at slots 1
and 2, 5 and 6, 9 and 10, and 13 and 14.
With current card cages, this limitation is removed so that the APS card pairs can be located anywhere
except BCC cards slots 7 and 8, and ASM card slot 15. An APS 1+1 redundant card pair must be in
adjacent slots (2,3 or 4,5 and so on).
Figure 13-10 APS 1+1 Redundancy
Working line
Protection line
17711
BPX switch
BPX switch
Working line
Protection line
17722
BPX switch
BPX switch
Summary of Contents for BPX 8650