29-7
Cisco BPX 8600 Series Installation and Configuration
Release 9.3.30, Part Number 78-12907-01 Rev. E0, May 2005
Chapter 29 Replacing Parts
Replacing an AC Power Supply
Replacing an AC Power Supply
BPX switches are powered by redundant power supplies; either power supply can supply the current
requirements of the node. The AC Power Supply is part of an assembly which is replaced as a single unit.
Access to the AC Power Supply assembly is from the front, but first, the Air Intake Grille must be
removed.
To remove a power supply, use the following procedure:
Step 1
If you haven’t already done so, check the status and output voltage of the power supplies at the node
using the
dspasm
command. Note which power supply is failed, A or B. Power supply A is on the right
side facing the rear of the node.
Step 2
Remove the Air Intake Grille. Locate the small access hole in the top, center of the Air Intake Grille.
Step 3
Fully insert a flat-bladed screwdriver (with a 1/4 in. blade) in the access hole.
Step 4
Rotate the screwdriver to release the spring latch holding the Air Intake Grille (see Figure 29-4). The
grille should pop out.
Figure 29-4 AC Power Supply Assembly
Step 5
Tilt the grille forward approximately a 45
°
angle, then lift if out and set it aside. This exposes the power
supply retainer bracket.
Step 6
With a flat-bladed screwdriver, loosen the retainer bracket hold-down screw in the center of the bracket
and tilt the bracket.
Step 7
Identify which power supply needs replacement. Power supply A is the unit on the left, B is on the right.
In most cases, the failed unit is identified by a front panel lamp indication.
SLOT A
SLOT B
Power supply
thumb screw
Power supply
retainer
Retainer
captive
screw
H8212
Slot B empty if
non-redundant
Power
supply
Power supply
plunger hole
Plunger
Power supply
thumb screw
Summary of Contents for BPX 8650
Page 49: ...P A R T 1 The BPX Switch ...
Page 50: ......
Page 159: ...P A R T 2 Installation ...
Page 160: ......
Page 273: ...P A R T 3 Initial Configuration and Network Management ...
Page 274: ......
Page 311: ...P A R T 4 Configuring Connections ...
Page 312: ......
Page 487: ...P A R T 5 Troubleshooting and Maintenance ...
Page 488: ......
Page 533: ...P A R T 6 BPX Specifications ...
Page 534: ......
Page 555: ...P A R T 7 Appendices ...
Page 556: ......