31-6
Cisco BPX 8600 Series Installation and Configuration
Release 9.3.30, Part Number 78-12907-01 Rev. E0, May 2005
Chapter 31 BPX Switch Cabling Summary
External Alarm Cabling
External Alarm Cabling
This cable (see Table 31-16) is for connecting network alarm outputs to the LM-ASM ALARM
OUTPUT connector only. Table 31-17
lists the pinouts for the network alarm outputs.
Table 31-13 E1 Connection 75 Ohm to EXT TMG on BCC-bc or BCC-3-bc
Connector
Description
BNC
Receive E1 from trunk
Table 31-14 E1 Connection 100/120 Ohm to EXT TMG on BCC-bc
Pin #
Description
2
Receive pair shield
3
Receive tip
11
Receive ring
Table 31-15 E1 Connection 100/120 Ohm to EXT 1 or EXT 2 on BCC-3-bc
Pin #
Description
Function
1
Transmit tip
Transmit T1 timing signal synchronized to the node
2
Transmit pair shield
3
Receive tip
Receive clock for synchronized clock source for node
4
Receive pair shield
7
Transfer timing tip
8
Transfer timing shield
9
Transmit ring
11
Receive ring
15
Transfer timing ring
Table 31-16 External Alarm Cabling
Cable Parameter
Description
Interface:
Dry-contact relay closure
Wire:
24 AWG, shielded, 6-pair
Connector:
DB-15, Subminiature, male
Summary of Contents for BPX 8650
Page 49: ...P A R T 1 The BPX Switch ...
Page 50: ......
Page 159: ...P A R T 2 Installation ...
Page 160: ......
Page 273: ...P A R T 3 Initial Configuration and Network Management ...
Page 274: ......
Page 311: ...P A R T 4 Configuring Connections ...
Page 312: ......
Page 487: ...P A R T 5 Troubleshooting and Maintenance ...
Page 488: ......
Page 533: ...P A R T 6 BPX Specifications ...
Page 534: ......
Page 555: ...P A R T 7 Appendices ...
Page 556: ......