31-5
Cisco BPX 8600 Series Installation and Configuration
Release 9.3.30, Part Number 78-12907-01 Rev. E0, May 2005
Chapter 31 BPX Switch Cabling Summary
LM-BCC Cabling
E1 Clock Cabling
Table 31-12 through Table 31-15 lists E1 clock cabling details.
Table 31-9
T1 Connection to XFER TMG on BCC-bc
Pin #
Description
1
Transfer timing ring
2
Transfer timing tip
3 & 4
Transfer timing shield
Table 31-10 T1 Connection to EXT TMG on BCC-bc
Pin #
Description
2
Receive pair shield
3
Receive tip
11
Receive ring
Table 31-11 T1 Connection to EXT 1 or EXT 2 on BCC-3-bc
Pin #
Description
Function
1
Transmit tip
Transmit T1 timing signal synchronized to the node
2
Transmit pair shield
3
Receive tip
Receive clock for synchronized clock source for node
4
Receive pair shield
7
Transfer timing tip
8
Transfer timing shield
9
Transmit ring
11
Receive ring
15
Transfer timing ring
Table 31-12 E1 Connector Pin Assignments for External Clock
Connector
Description
Cable Type:
75-ohm coax cable for unbalanced connection or 100–120-ohm twisted pair
for balanced connection. Two cables/pairs (1 transmit, 1 receive) per E1 line.
Cable Connector:
Two female BNC for unbalanced connection; male DB15 for balanced
connection. See Table 31-13
and Table 31-15 for pinouts.
Max. Cable Length:
Approximately 100 meters maximum between the BPX switch and the first
repeater or CSU. Equalizer for cable length.
Summary of Contents for BPX 8650
Page 49: ...P A R T 1 The BPX Switch ...
Page 50: ......
Page 159: ...P A R T 2 Installation ...
Page 160: ......
Page 273: ...P A R T 3 Initial Configuration and Network Management ...
Page 274: ......
Page 311: ...P A R T 4 Configuring Connections ...
Page 312: ......
Page 487: ...P A R T 5 Troubleshooting and Maintenance ...
Page 488: ......
Page 533: ...P A R T 6 BPX Specifications ...
Page 534: ......
Page 555: ...P A R T 7 Appendices ...
Page 556: ......