![background image](http://html1.mh-extra.com/html/carrier/vector-1800-mt/vector-1800-mt_operation-and-service-manual_2564194297.webp)
9-4
62-11039
INDICATION/
TROUBLE
POSSIBLE CAUSES
REFERENCE
SECTION
9.2 BATTERY CHARGER
Input fuse blows when charger is
turned on
Short in 12 volt wiring causing
overload of charger
Locate and re-
move short
Input fuse blows repeatedly, even
when not connected
Internal short
Replace
Charger does not taper back after
charging for a few minutes
Bad cell in battery
Test battery for
defect accord-
ing to battery
manufacturer’s
instructions
Defective charger
Replace
Charger does not charge
Open input circuit breaker
Charger is not receiving AC input
Reset
Using a voltme-
ter, confirm
charger is re-
ceiving correct
(230v) AC volt-
age. If not
check input
connections.
Charger output is not connected to 12 volt battery
Check output
wiring connec-
tions to battery.
Defective charger
Replace
Low output voltage measured
across charger output
Battery not connected to charger. It is
normal to measure 12 volts or less across
charger output with no battery connected
Check charging
leads from
charger to bat-
tery
Reverse polarity connection to
battery has caused charger to
stop charging
Internal DC fuse blown and possible
damage to current carrying components
Replace
Summary of Contents for VECTOR 1800 MT
Page 1: ......
Page 2: ...OPERATION SERVICE MANUAL for VECTOR 1800 MT Trailer Multi Temp Refrigeration Units ...
Page 19: ...1 5 62 11039 1 3 SAFETY DECALS ...
Page 20: ...1 6 62 11039 62 03958 00 Heat Warning 62 03957 01 High Voltage 62 60280 00 Standby Safety ...
Page 21: ...1 7 62 11039 ...
Page 303: ...10 1 62 11039 ...
Page 310: ...10 8 62 11039 BASED ON ENGINEERING SCHEMATIC 62 60926 REV G NEXT SHT ...
Page 311: ...10 9 62 11039 FROM PREVIOUS SHT ...