Table 3-1. UNIT DATA
* Also appear in Configurations
+ May or may not be displayed depending on functional parameter settings
DATA
DEFINITION
SUCTION PRESSURE
Compressor suction pressure
DISCHARGE PRESSURE
Compressor discharge pressure
EVAPORATOR PRESSURE Suction pressure in the evaporator section
ENGINE COOLANT TEMP
Engine coolant temperature
RETURN AIR TEMP
Compartment 1 return (air entering evaporator) air temperature
C2 RETURN AIR TEMP
Compartment 2 return (air entering evaporator) air temperature
C3 RETURN AIR TEMP
Compartment 3 return (air entering evaporator) air temperature
SUPPLY AIR TEMP
Compartment 1 supply (air leaving evaporator) air temperature
C2 SUPPLY AIR TEMP
Compartment 2 supply (air leaving evaporator) air temperature
DELTA--T
Return air temperature minus Supply air temperature in compartment 1
only
AMBIENT AIR TEMP
Ambient (air entering condenser) air temperature
DEFROST TERM TEMP 1
Compartment 1 defrost termination temperature
C2 DEFROST TERM TEMP Compartment 2 defrost termination temperature
C3 DEFROST TERM TEMP Compartment 3 defrost termination temperature
SUCTION LINE TEMP
Suction line temperature at the compressor
EVAP OUTLET TEMP
Suction line temperature at the evaporator outlet
DISCHARGE TEMP
Compressor discharge temperature
BATTERY
Battery voltage
CURRENT DRAW
Battery charging or discharging amps.
ENGINE RPM
Engine revolutions per minute
UNIT AC CURRENT #1
High voltage current draw on circuit #1.
UNIT AC CURRENT #2
High voltage current draw on circuit #2.
FUEL LEVEL
% of fuel in tank. (This is only shown when 0% -- 100% sensor is config-
ured ON.)
SUCTION MOD VALVE
% open of CSMV
EXPANSION VALVE
% open of EVXV
START MODE
AUTO if the engine will start automatically
MANUAL if the engine must be started manually
INSTALLED OPTIONS
INTELLISET INSTALLED
Applies only if unit has these installed options.
SOFTWARE REVISION
Revision of the software that is operating the microprocessor
DISPLAY SOFTWARE REV Revision of the software that is operating the display
CONTROL SERIAL #
Serial Number of the microprocessor
*
TRAILER ID #
ID (as entered by the user)
*
UNIT SERIAL #
Unit serial number
Summary of Contents for VECTOR 1800 MT
Page 1: ......
Page 2: ...OPERATION SERVICE MANUAL for VECTOR 1800 MT Trailer Multi Temp Refrigeration Units ...
Page 19: ...1 5 62 11039 1 3 SAFETY DECALS ...
Page 20: ...1 6 62 11039 62 03958 00 Heat Warning 62 03957 01 High Voltage 62 60280 00 Standby Safety ...
Page 21: ...1 7 62 11039 ...
Page 303: ...10 1 62 11039 ...
Page 310: ...10 8 62 11039 BASED ON ENGINEERING SCHEMATIC 62 60926 REV G NEXT SHT ...
Page 311: ...10 9 62 11039 FROM PREVIOUS SHT ...