2.11 COMPRESSOR DATA
Table 2-6. Compressor Data
Compressor Model
06D
No. Cylinders
6
No. Unloaders
2
Weight
260 lbs (118 kg)
Oil Charge
7.6 pints (3.6 L)
Approved OIl
Mobil Arctic EAL 68
2.12 REFRIGERATION SYSTEM DATA
a. Defrost Air Switch (DAS)
Initiates Defrost:
1.40
¦
.07 inch WG (35
¦
1.8 mm)
b. Defrost Timer (micro controlled)
1.5h, 3h, 6h, or 12 hours
c. Evaporator High Temperature Safety (EVHTS)
Opens at: 130
°
¦
1
°
F (55
°
¦
0.5
°
C)
Closes at: 100
°
¦
1
°
F (37.8
°
¦
0.5
°
C)
d. Defrost Termination Thermistor (DTT)
Opens at: 55
°
¦
0.5
°
F (12.8
°
¦
1
°
C)
Closes at: 40
°
¦
1
°
F (4.4
°
¦
0.5
°
C)
e. Relief Valve Setting
537
44 psig (
3
7
3 Bar)
f. High Pressure Switch (HP1)
Cutout : 465
¦
10 psig (34
¦
0.7 bar)
Cut-in : 350
¦
10 psig (24
¦
0.7 bar)
g. Engine Oil Pressure Switch (ENOPS)
Closes at : Oil pressure above15 psig (1 bar)
Opens at : Oil pressure below12 psig (0.82 bar)
Type: TES 2
h. Unit Dry Weight: 2062 LBS. (937KG)