62-11039
5-12
5.2.2 Component Test Mode
NOTE
To enter Component Test Mode Refer to Sec-
tion 5.2.
Component Test Mode allows the Technician to
energize individual circuits for 5 minutes at a time. The
engine is not allowed to start when the Micro is in
Component Test Mode.
From the Main Menu, select Component Test Mode,
and press =. Use the UP or Down arrow keys to scroll
through the list when
“
↑ ↓
TO SCROLL, THEN = TO SELECT” appears in the
MessageCenter. Press = to select the component you
wish to test. For example, if the Cool Light is selected,
the Cool Light on the Light Bar will come on, and
“COOL LIGHT OFF IN 5 MINUTES” will appear in the
MessageCenter. The minutes will count down to 0 at
which time the Cool Light circuit will be de-energized,
and the MessageCenter will display the last component
tested.
The test may be stopped at any time by turning the
Start/Run--Off Switch to the Off position, or by pressing
and holding the = key for 6 seconds. Should you need
more than 5 minutes, the timer may be reset to 5
minutes anytime during the test by pressing the = key.
The timer may only be reset once during each test. After
the 5 minute timer expires, the MessageCenter will
return to the Component Test Mode Menu, and display
the last component tested.
To retest the same component and circuit again, press
=. To select another component to test, press the UP or
DOWN Arrow keys to select another component, and
press = to select.
To go to Diagnostic Mode or
Configuration Mode, select Main Menu and press =.
The only keys that operate during Component Test
Mode are the Alarm and Select keys. The alarm list is
available for you to look at any active or inactive alarms.
The Select key will only allow access to the Current
Draw item in the Data List.
When Component Test Mode is selected, the Main
Display will show OFF.
Summary of Contents for VECTOR 1800 MT
Page 1: ......
Page 2: ...OPERATION SERVICE MANUAL for VECTOR 1800 MT Trailer Multi Temp Refrigeration Units ...
Page 19: ...1 5 62 11039 1 3 SAFETY DECALS ...
Page 20: ...1 6 62 11039 62 03958 00 Heat Warning 62 03957 01 High Voltage 62 60280 00 Standby Safety ...
Page 21: ...1 7 62 11039 ...
Page 303: ...10 1 62 11039 ...
Page 310: ...10 8 62 11039 BASED ON ENGINEERING SCHEMATIC 62 60926 REV G NEXT SHT ...
Page 311: ...10 9 62 11039 FROM PREVIOUS SHT ...