62-11039
6-4
MessageCenter MESSAGES
Message
Description
PRETRIP FAIL IN TEST XX
Some of the pretrip tests did not pass and the pretrip was not com-
pleted.
PRETRIP PASS
All of the pretrip tests were ok.
PRETRIP STOPPED BY USER
Pretrip has been stopped by user.
PRODUCTSHIELD: HIGH AIR ON
The unit is operating in ProductShield High Air which overrides nor-
mal unit operation. See Section 4.6
PRODUCTSHIELD: WINTER ON
The unit is operating in ProductShield Winter which overrides nor-
mal unit operation. See Section 4.6
PRODUCTSHIELD: ECONO ON
The unit is operating in ProductShield Econo which overrides nor-
mal unit operation. See Section 4.6
RECOVER / LEAK CHK / EVAC MODE
This message will be displayed when the unit is in Service Mode
and the system is ready for recovery and leak testing.
REMOVE JUMPER
The Configuration / Technician Test Mode has been entered. Re-
move the jumper wire before continuing.
SAME SW, = TO LOAD,
↑
TO CANCEL
A Program PC Card has been inserted into the PC Card slot, and
the program on the PC Card is the same as the program currently
in the Micro. Press = to reload the same program or
↑
to cancel
and remove card.
SERVICE MODE
Selection in Configuration and Test Modes which allows servicing
of the refrigeration system.
SETPOINT CHANGED
The new setpoint has been entered (saved into Micro memory), the
new setpoint will be used.
SETPOINT NOT CHANGED
The new setpoint has NOT been entered (NOT saved into Micro
memory), the old setpoint will be used.
SETTING SMV: XXX %
The Start/Run--Off switch has been placed in the Start/Run position
and at least one compartment is on and CSMV is opening.
SLEEP MODE, OFF / ON TO WAKE
The unit is cycled off in Sleep Mode. Turn the Start/Run--Off
Switch OFF, then back ON to wake the Micro up.
SLEEP WARNING: NO TEMP CONTROL
The unit is running in Sleep Mode.
SMV CLOSING: WAIT XXX SECONDS
Power Up and CSMV is closing. XX is number of seconds remain-
ing until valve is fully closed.
START STOP LOCKED
The setpoint has been locked into the Start--Stop mode. Continu-
ous Run can not be selected.
START/STOP MODE SELECTED
Start/Stop Mode has been selected.
STATUS OK--COMPARTMENT X
Everything is working well where X is the compartment number.
TEST #1 to #15
Pretrip is currently running this test and is x% complete
TIME SELECTION NOT CHANGED
A time change was started but not in Configuration List.
TRIP START ENTERED
The Trip start marker has been placed in the Data Recorder.
UNIT BATTERY DEAD --xx V
The unit battery has dropped below 7 volts for more than 10 sec-
onds.
UNIT OFF
All compartment enable switches are Off
UNIT SHUTDOWN -- SEE ALARM LIST
An active shutdown alarm has shut the unit down.
UNKNOWN CARD -- REMOVE CARD
A defective PC Card has been inserted into the PC Card slot. The
Micro can not recognize any data on the card. The card may be
safely removed from the Micro.
WARNING: DIESEL RESTART ON
When electric power is not available while the unit is operating in
Electric Standby mode, the unit will switch to diesel operation.
WARNING: NO TEMP CONTROL
The temperature sensor(s) have failed In a compartment with a
frozen setpoint and the compartment is operating only in cool
mode.
WRONG UNIT TYPE, REMOVE CARD
A config PC Card has been inserted into the PC Card slot. The
unit model family type on the PC card is not in the same unit family
type as the controller. The card may be safely removed from the
Micro.
Summary of Contents for VECTOR 1800 MT
Page 1: ......
Page 2: ...OPERATION SERVICE MANUAL for VECTOR 1800 MT Trailer Multi Temp Refrigeration Units ...
Page 19: ...1 5 62 11039 1 3 SAFETY DECALS ...
Page 20: ...1 6 62 11039 62 03958 00 Heat Warning 62 03957 01 High Voltage 62 60280 00 Standby Safety ...
Page 21: ...1 7 62 11039 ...
Page 303: ...10 1 62 11039 ...
Page 310: ...10 8 62 11039 BASED ON ENGINEERING SCHEMATIC 62 60926 REV G NEXT SHT ...
Page 311: ...10 9 62 11039 FROM PREVIOUS SHT ...