62-11039
5-7
CONFIGURATION
SELECTIONS
DESCRIPTION
PM (1--5) RESET INTERVAL
NOT DISPLAYED
ENGINE HOURS
OFF or
50 TO 30,000 HRS
in 50 hr increments
SWITCH ON
HOURS
OFF or
50 TO 30,000 HRS
in 50 hr increments
STANDBY HOURS
OFF or
50 TO 30,000 HRS
in 50 hr increments
START CYCLES
1,000 TO 90,000
CYCLES
OFF or
in 1,000 cycle in-
crements
HIGH SPEED
HOURS
OFF or
50 TO 30,000 HRS
in 50 hr increments
0 = PM (1--5) is not being used.
ENGINE HOURS = PM (1--5) is connected to the
engine hour meter. The reset interval will be (50 –
30,000 hrs).
SWITCH ON HOURS = PM (1--5) is connected to
the switch on hour meter. The reset interval will be
(50 – 30,000 hrs).
STANDBY HOURS = PM (1--5) is connected to the
Standby Run Time hour meter. The reset interval
will be (50 – 30,000 hrs).
START CYCLES = PM (1--5) is connected to the
clutch cycle meter. This meter counts every time
the engine starter engages. The reset interval will
be (1,000 to 90,000 cycles)
HIGH SPEED HOURS = PM (1--5) is connected to
the high engine speed hour meter, which counts
only high speed engine hours. The reset interval
will be (50 – 30,000 hrs).
PRODUCTSHIELD SETUP
Note: ProductShield is only avail-
able when IntelliSet is installed.
This message will only appear if ProductShield is
installed. The information set in the following con-
figurations can be read in the Unit Data List.
•
PRODUCTSHIELD ECONO
OFF
GO TO S/S
GO TO CONT
OFF = ProductShield Econo is OFF
GO TO START/STOP = Allows unit to be set for
and operate in Continuous Run until ambient tem-
perature falls
within
a user--defined range when
unit will go to Start/Stop. This allows fuel savings
while offering Continuous Run operation protection
when ambient is outside range. Unit will return to
Continuous Run when ambient goes beyond range.
GO TO CONTINUOUS = Allows unit to be set for
and operate in Start/Stop until ambient temperature
falls
outside
a user--defined range when unit will go
to Continuous Run. This provides continuous air
flow and good product protection for extreme ambi-
ent temperatures. Unit will return to Start/Stop
when ambient comes back inside range.
The minimum range allowed for this selection is
10
°
F (5.5
°
C).This means that the MIN temperature
will never be closer to the MAX temperature than
10
°
•
ECONO MIN. TEMP
--19
°
F to +119
°
F
(--28.3
°
C to
+48.3
°
C )
in 0.5
°
F or
°
C
increments
Default:
119
°
F
(48.3
°
C )
OFF
Select the lower limit of the ambient range desired
for this parameter. See Section 4.6 for more infor-
mation on Econo Min. Temp.
Summary of Contents for VECTOR 1800 MT
Page 1: ......
Page 2: ...OPERATION SERVICE MANUAL for VECTOR 1800 MT Trailer Multi Temp Refrigeration Units ...
Page 19: ...1 5 62 11039 1 3 SAFETY DECALS ...
Page 20: ...1 6 62 11039 62 03958 00 Heat Warning 62 03957 01 High Voltage 62 60280 00 Standby Safety ...
Page 21: ...1 7 62 11039 ...
Page 303: ...10 1 62 11039 ...
Page 310: ...10 8 62 11039 BASED ON ENGINEERING SCHEMATIC 62 60926 REV G NEXT SHT ...
Page 311: ...10 9 62 11039 FROM PREVIOUS SHT ...