2-12
62-11039
2.6.3 Microprocessor Component Description
And Location
The microprocessor controller consists of two modules
-- the control module (See Figure 2-7) and display and
keypad module (See Figure 2-8). The control module is
housed in the control box on the lower roadside (right)
corner of the unit. This control module consists of a logic
board and an input/output board. The control module
contains externally accessible relays and fuses. The
display and keypad module is located for driver access
at the lower roadside corner of the unit.
The processor board in the control module includes the
microprocessor, program memory and necessary
input/output circuitry to interface with the unit. The
microprocessor is totally self contained and does not
contain any serviceable components.
The display board is mounted in the keypad and display
module. The board includes the LCD display, keypad
and keypad interface.
The keypad & display module provides the user with a
panel to view and control the functions of the
refrigeration unit. The module consists of a switch,
keypad, MessageCenter, and Main Display. Setpoints
and other system information are selected using the
keypad.
Figure 2-8 shows the display & keypad
module.
CAUTION
Under no circumstances should anyone attempt to repair the Logic or Display Boards. Should a
problem develop with either of these components, contact your nearest Carrier Transicold dealer for
replacement.
a. Control Module
Figure 2-7 shows the Control Module. The Control
Module has 3 relays and 4 fuses that are user
accessible.
The PC card slot is also shown in Figure 2-7. This card
slot is used with all Carrier Transicold PC Cards. The
controller automatically detects the presence and type
of PC Card inserted and responds accordingly. The
different types of PC Cards are:
S
Download Card for copying unit data from Data
Recorder.
S
Options PC Card for installing optional software
programs
S
Configuration PC Card for setting the Microprocessor
Functions,
Configurations
and
Data
Recorder
configurations.
S
Program PC Card for upgrading the microprocessor
software.
There are three LEDs associated with the function of the
PC card slot. These are:
•
A green Micro Status LED which will blink steadily once
per second indicating that the microprocessor is
operating and will blink every 0.5 seconds if there is no
software or if it is loading software.
•
A green (PC) Card Status LED which comes on when
there is a PC card inserted in the slot. This LED will:
1. Blink every 0.5 seconds when data is being trans-
ferred to or from the PC Card, and Will be on steady
when the operation is complete and the PC Card
may be removed.
2. During Download, the light will blink once per second
and will blink every 1.5 seconds when the Download
is complete.
•
A red (PC) Card Fault LED blinks if there is a problem
transferring data from the PC card that has been
plugged into the PC card slot. The red LED will continue
to blink until the PC card is removed. The LED will also
blink if there is an error reading the card. Check the
MessageCenter for description of error.
Summary of Contents for VECTOR 1800 MT
Page 1: ......
Page 2: ...OPERATION SERVICE MANUAL for VECTOR 1800 MT Trailer Multi Temp Refrigeration Units ...
Page 19: ...1 5 62 11039 1 3 SAFETY DECALS ...
Page 20: ...1 6 62 11039 62 03958 00 Heat Warning 62 03957 01 High Voltage 62 60280 00 Standby Safety ...
Page 21: ...1 7 62 11039 ...
Page 303: ...10 1 62 11039 ...
Page 310: ...10 8 62 11039 BASED ON ENGINEERING SCHEMATIC 62 60926 REV G NEXT SHT ...
Page 311: ...10 9 62 11039 FROM PREVIOUS SHT ...