Key Descriptions
UP ARROW and DOWN ARROW Keys
These keys allow you to change the
setpoints or other displayed data of the
system.
They also allow you to scroll
through the Unit Data List, Function
Parameters List, Alarm List, etc.
EQUAL Key (ENTER)
The EQUAL key is used for many things
including entering a setpoint, changing a
Functional Parameter, clearing alarms, and
locking the data menu.
MANUAL DEFROST Key
The MANUAL DEFROST key is used to
initiate a defrost cycle when the proper
conditions are met.
ALARM LIST Key
The ALARM LIST key allows you to view the
alarms stored in the microprocessor. The
alarm
list
is
displayed
in
the
MessageCenter.
Pressing the ALARM
LIST key once displays the active alarm list.
Each successive press cycles through the
list to the end. To view the inactive alarm list,
Refer to Section 3.13.
START--STOP/CONTINUOUS Key
This key allows you to change from
Start--Stop operation to Continuous Run
operation. In Start--Stop operation, when
the controller is in Off--Cycle mode, the unit
will not be running. During Off--Cycle mode,
the
microprocessor
monitors
box
temperature, battery voltage and engine
coolant temperature and will restart the unit
when needed.
SELECT Key
Press the SELECT key to scroll through the
menu selections. One of the five standard
and 1 optional menu selections will appear
in the MessageCenter when the SELECT
key is pressed. These are: TO VIEW
HOURMETERS, TO START PRETRIP, TO
VIEW DATA, TO VIEW SETTINGS, TO
MARK TRIP START or TO VIEW PRINT
MENU, or one optional selection --TO VIEW
INTELLISET. Repeated pressing of the
SELECT key will sequence the menu
through these selections. The menu wraps
around. Press the SELECT key until the
desired menu selection appears in the
MessageCenter.
The five standard selections are:
•
TO VIEW HOURMETERS
-- Displays the
hours for individual hour meters. Refer to
Section 3.15.
•
TO VIEW PRETRIP
-- Used to initiate a
pretrip. Refer to Section 3.5.
•
TO VIEW DATA
-- Displays Unit Data.
Refer to Section 3.14.
•
TO VIEW SETTINGS
-- Displays unit
Functional Parameter settings. Refer to
Section 3.16.
•
TO MARK TRIP START
-- This menu
selection is only used with the Data
Recorder. It is used to record a Trip Start
event which is logged in the Data Recorder.
This records the time and date of the
beginning of the trip. Data can then be
downloaded and reviewed by trip, making
data review much easier. Refer to Section
3.11.
•
TO VIEW PRINT MENU
-- Enables the
user to use hand--held Strip Print printer kit
P/N 12--00543--10.
The optional selection is:
•
TO VIEW INTELLISET
-- Refer to Section
3.20.1.
MANUAL
DEFROST
ALARM LIST
START--STOP/
CONTINUOUS
SELECT
Summary of Contents for VECTOR 1800 MT
Page 1: ......
Page 2: ...OPERATION SERVICE MANUAL for VECTOR 1800 MT Trailer Multi Temp Refrigeration Units ...
Page 19: ...1 5 62 11039 1 3 SAFETY DECALS ...
Page 20: ...1 6 62 11039 62 03958 00 Heat Warning 62 03957 01 High Voltage 62 60280 00 Standby Safety ...
Page 21: ...1 7 62 11039 ...
Page 303: ...10 1 62 11039 ...
Page 310: ...10 8 62 11039 BASED ON ENGINEERING SCHEMATIC 62 60926 REV G NEXT SHT ...
Page 311: ...10 9 62 11039 FROM PREVIOUS SHT ...