5.6.4 Functional Parameters Via Keypad
a. Refer to Section 3.16 for list of available Micropro-
cessor Functional Parameters.
b. Press the Select Key, until
PRESS
↑ ↓
TO VIEW SETTINGS appears in the
MessageCenter
c. Pressing the Up Arrow Key will bring
↑ ↓
TO SCROLL, THEN = TO SELECT into the
MessageCenter.
d. Press the Up Arrow Key to go to the first Functional
Parameter. The MessageCenter will show
DEFROST TIMER SET FOR X HRS.
e. To keep this setting and go to the next setting, press
the Up Arrow Key.
f. To change the parameter, press the = Key.
↑ ↓
TO SCROLL, = TO SAVE will show in the
MessageCenter.
g. Press the Up Arrow Key and the parameter will be
flashing on and off, indicating that changes are pos-
sible.
h. Press the Up Arrow Key to scroll through the avail-
able selections for the parameter. When the setting
you desire appears, press the = Key to enter and
save your selection.
i. Repeat steps e. thru h. and continue through the en-
tire list of Functional Parameters.
j. Leave the microprocessor powered up as you con-
tinue with the next section.
5.6.5 DataRecorder Via
ReeferManager PC Program
NOTE
If the factory settings are used, you can skip this
section and proceed to Hourmeter Setup.
a. Refer to Section 3.19 for list of DataRecorder Set-
ups.
b. Power up the microprocessor. If it is not already
powered up, refer to directions under Microproces-
sor Setup – Functional Parameters via Keypad, Sec-
tion
5.6.4
above.
c. Connect your computer to the Download Port of the
unit (use cable 22--001737) and start the
ReeferManager program. You will need ReeferMa-
nager version 03.00.00 or higher.
NOTE
ReeferManager 03.00.00 is
REQUIRED
in or-
der to view, change and send new features to
and from the microprocessor.
d. In ReeferManager, go to the Serial Operations Tab,
and then click on Data Recorder/Microprocessor
setup button.
e. Select the Sensors to be recorded and whether you
wish averaged or snapshot recordings (averaged is
recommended for all temperature sensors; snap-
shot is recommended for voltage, amperage, &
RPM).
f. When the setup is correct, press the Send button to
send the new settings to the microprocessor.
g. Verify that the settings were sent, by waiting for the
confirmation pop up message.
NOTE
If the data recorder date and time were not set
earlier, they can be set from this screen by click-
ing on Tools>set date and time.
h. Leave the microprocessor powered up as you con-
tinue with the next section.
5.6.6 Engine And Switch--on Hour Meters Via
ReeferManager PC Program
a. Start the ReeferManager program. Go to the Serial
Operations Tab.
b. Click on Microprocessor Setup button.
c. In the upper left menu bar, click on Tools>Set New
Micro Hours.
d. At this screen, enter the Engine and Switch On hours
that were recorded in step b. of Section 5.6.1. Send
the new readings to the microprocessor.
NOTE
The program will only allow hours to be
changed until the Engine Hourmeters reach 25.
Once the Hourmeter shows 25 or more hours,
no changes may be made to it. BE CERTAIN
THAT YOU HAVE ENTERED ALL HOUR AND
CYCLE
METER
NUMBERS
BEFORE
PRESSING THE OK BUTTON.
e. Your computer may now be disconnected and turned
off.
Summary of Contents for VECTOR 1800 MT
Page 1: ......
Page 2: ...OPERATION SERVICE MANUAL for VECTOR 1800 MT Trailer Multi Temp Refrigeration Units ...
Page 19: ...1 5 62 11039 1 3 SAFETY DECALS ...
Page 20: ...1 6 62 11039 62 03958 00 Heat Warning 62 03957 01 High Voltage 62 60280 00 Standby Safety ...
Page 21: ...1 7 62 11039 ...
Page 303: ...10 1 62 11039 ...
Page 310: ...10 8 62 11039 BASED ON ENGINEERING SCHEMATIC 62 60926 REV G NEXT SHT ...
Page 311: ...10 9 62 11039 FROM PREVIOUS SHT ...